Page 1: ...20F Carpet And Upholstery Cleaner Model No 100 650 225 11 gal Extractor CLEANMASTER 11015 47 TH AVENUE WEST MUKILTEO WA 98275 U S A FAX 1 800 426 4225 WEBSITE www cleanmaster com CUSTOMER SERVICE 1 425 775 7276 Operator and Parts Manual ...

Page 2: ...e or mail from any authorized parts and service center distributor or directly from Cleanmaster This machine will provide excellent service However the best results will be obtained at minimum costs if The machine is operated with reasonable care The machine is maintained regularly per the maintenance instructions provided The machine is maintained with manufacturer supplied or equivalent parts MA...

Page 3: ... wet hands Keep cord away from heated surfaces Report machine damage or faulty operation immediately Follow mixing and handling instructions on chemical containers Connect hoses before turning on pump Be sure chemicals are safe and non toxic 4 Before leaving or servicing machine Turn off machine Unplug cord from wall outlet 5 When servicing machine Unplug cord from wall outlet Avoid moving parts D...

Page 4: ...refully check carton for signs of damage Report damages at once to carrier The machine is shipped fully assembled and is ready for use 2 Connect hoses and tool to be used Figure1 3 Using a clean bucket or hose fill solution tank with 41 liters 11 gallons of hot water 60 C 140 F maximum Figure 2 WARNING Flammable materials can cause an explosion or fire Do not use flammable materials in tank s 4 Ad...

Page 5: ...ctivate vacuum and pump switches Figure 4 2 Take carpet cleaning wand in hand and squeeze valve trigger while moving the tool in short forward and backward strokes over the carpet Figure 5 WHILE OPERATING 1 Overlap each path by 50 mm 2 in Warning Flammable materials or reactive metals can cause an explosion or fire Do not pick up 2 Periodically check for excessive foam buildup in recovery tank Use...

Page 6: ...clean water at the end of the day DRAINING SOLUTION TANK 1 Remove empty out nozzle from its storage bracket Figure 9 and attach to end of solution hose 2 Place empty out nozzle over a bucket and turn on pump until all the solution has been pumped from solution tank 3 Replace empty out nozzle to its storage location FREEZE PROTECTION 1 After draining solution tank as described in steps one and two ...

Page 7: ...on the pump out switch Figure 12 The flood pump will not come on until the level inside the recovery tank activates the float switch 5 Proceed to clean When completed turn off the pump out switch and manually drain the last amount of water from the recovery tank 6 Never turn on the pump out switch without a garden hose connected FLOOD PUMP REMOVAL 1 Unlatch locking arms of bayonet coupler Figure 1...

Page 8: ...mical containers 3 Inspect cord and cord grip for damage Replace immediately if damaged 4 Lubricate metal shaft on recovery tank drain with water resistant oil 5 Lubricate female hose couplers with lightweight oil MONTHLY MAINTENANCE Every 80 Hours of Operation 1 Lubricate wheels with water resistant oil 2 Inspect machine for water leaks and loose hardware QUARTERLY MAINTENANCE Every 250 hours of ...

Page 9: ...cuum motor does not operate Worn carbon brushes Contact Service Center Faulty switch or wiring Contact Service Center Float switch tangled in cord Untangle cord in vacuum tank Filter screen clogged Clean filter screen under flood pump Flood pump does not work Output of flood pump disconnected Connect quick coupler in waste tank Recovery tank drain valve open Close valve Defective recovery tank lid...

Page 10: ... gal RECOVERY TANK CAPACITY 38L 10 gal SOLUTION PUMP 120 V 10 2 bar 150psi 1 04 A VACUUM MOTORS 2 x 2 STAGE 2 120 V 8 6 A 1032 W FLOOD PUMP 120 V 5 A 600 W 56 8 LITERS 15 GAL MIN SEALED WATER LIFT 3810 mm 150 in TOTAL POWER CONSUMPTION 120V 20 A 1800 W POWER CORDS 1 15 2m 50 ft 3 12 DECIBEL RATING 3 METERS 10 FT FROM MACHINE ON CARPET 78 db A 711 mm 28 in 1016 mm 40 in 450 mm 17 7 in 902 mm 35 5 i...

Page 11: ...36400 E3 Raptor 220F 05 01 11 ELECTRICAL DIAGRAM RAPTOR 220 120 V WIRING DIAGRAM ...

Page 12: ...36400 E3 Raptor 220F 05 01 12 PARTS LIST RAPTOR 220 TANK GROUP ...

Page 13: ...2 HOSE 2 PART DESCRIPTION QTY F 11 Q C 1 4 SOC BR SHUT OFF 2 G 03 19 O RING VITON 2 020 BLKHD 1 J 48CLNMSTR LID SOLUTION GRNGRANITE CM 1 J 49GRNGRNT LID ROTO GREEN GRANITE 1 J 57 SPACER ROTO 1 5 OD X 1 0 ID 1 J 57 5 SPACER ROTO 3 OD X 2 4 ID 1 K 09 6 CORD 50 12 3 SJT YELLOW W LOCK 1 K 16 92 BUSHING RELIEF 3 8 NPT 1 K 16 96 BUSHING RELIEF 1 2 NPT 1 K 16 97 NUT NYLON BUSHING REL 1 2 1 K 17 5 CLAMPS ...

Page 14: ...36400 E3 Raptor 220F 05 01 14 PARTS LIST RAPTOR 220 BASE GROUP ...

Page 15: ...AC SEAL BASE 1 C 23 8 WHEEL 10 1 2 BORE 2 C 59 PUSHNUT FASTNER 1 2 CAP 2 PART DESCRIPTION QTY C 95 VELCRO ONE WRAP STRAP 1 2 X 12 1 D 17 90 ST ELBOW 1 4 NPT 1 D 20 03 ELBOW 90 3 8NPT X 6 SAE 1 E 14 CUFF 1 1 2SLIP X 1 1 4HOSE 1 F 09 Q C 1 4 PLUG BR SHUT OFF 1 K 17 3 CLAMP NYLON CABLE 3 16 2 K 17 4 CLAMP NYLON CABLE 1 4 2 M 0790 5 AXIL ROD 1 2 ECONO 1 M 0791 AXIL ROD 1 2 1 M 0791 3 PIVOT TUBE 3 400 ...

Page 16: ...D 150 PSI COMP ASM 1 L 23 76 SWITCH ASM 150 PSI SH FL 1 L 22 65 CHECK VALVE ASM 100 PSI SH FL 1 L 24 12 HEAD PUMP DIAPHRAGM 1 L 23 74 BYPASS VALVE ASM 150 PSI SH FL 1 L 23 9 DIAPHRAGM SOLID DRIVE ASM 150PSI 1 SL 23 75 MOTOR 150 PSI 120V SH FL PLG 1 RECOMMENDED STOCK ITEMS SL 23 7 N A L 23 9 SL 23 75 L 23 76 L 22 65 L 24 12 L 23 74 ...

Page 17: ...16 18 NYLOCK ZINC 2 C 07 9 GRIP FLRTOOL 1 1 2 X 6 1 D 15 2 45 ST ELBOW 1 4 NPT 1 D 41 NIPPLE 1 4 NPT CLOSE BR 1 PART DESCRIPTION QTY F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 23 VALVE KNGSTN STD S BND 1 H 37 JET 11006 E VEE BRASS 1 M 16 5 HOE HANDLE ECONO FLRTL 1 M 16 5A U CLAMP SUPP HOE HNDL EC 1 M 19 5 WAND FLOORTOOL COMP ECONO 1 SC 82 TRIGGER COMP KNGSTN VALVE 1 SE 06 7 47 HOSE 1 4 SOL 47 FLRTL ECO 1 R...

Page 18: ...45 ST ELBOW 1 4 NPT 1 D 41 NIPPLE 1 4 NPT CLOSE BR 1 F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 23 VALVE KNGSTN STD S BEND 1 PART DESCRIPTION QTY G 23 5 VALVE KNSTN HP S BEND 1 H 02 5 BODY TEE JET 1 4 BRASS 2 H 03 CAP NUT TEE JET BRASS 2 H 18 5 JET 11003 TEE BRASS 2 H 18 7 JET 110015 E TEE BRASS 2 M 16 5 HOE HANDLE ECONO FLRTL 1 M 16 5A U CLAMP SUPP HOE HNDL EC 1 M 20 WAND S BND FLTL COM W HD 1 SC 82 TRIGG...

Page 19: ...OFF 1 G 04 5 GUIDE VALVE STEM HEX BRASS 1 G 05 5 STEM VALVE SS 4 DETAIL TOOL 1 G 08 5 SPRING VALVE 4 UPH TOOL 1 PART Description QTY GR 2 006N70 O RING 2 006 BUNA 70DR 2 GR 2 011N70 O RING 2 011 BUNA 70DR 1 GR 2 013N70 O RING 2 013 BUNA 70DR 1 H 03 5 CAP NUT TEE JET POLYPRO 1 H 18 8 JET 110015 STD FLAT SPRYTIP PLSTIC 1 J 62 VALVE 4 DETAIL TOOL AS MOLDED 1 J 63 TRIGGER 4 DETAIL TOOL 1 J 64 ELBOW 4 ...

Page 20: ...N A RETURN AUTHORIZATION Prior to shipping any part assembly or machine to Cleanmaster a Return Authorization Number must be requested from Cleanmaster and displayed prominently on the outside of all packages containing parts or machines for warranty consideration to be processed and in effect A Return Authorization can be obtained by calling Cleanmaster Service Department at 1 425 775 7276 The ma...

Page 21: ...omponent s with any part s other than genuine Cleanmaster parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Raptor This warranty shall not cover any Raptor machine housing part or assembly if there is evidence of misus...

Page 22: ...achine component s with any part s other than genuine Cleanmaster parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Raptor This warranty shall not cover any Raptor machine housing part or assembly if there is evidence ...

Reviews: