6
The HALO half masks are approved and may be used without the Head Cover with either the HE Filter HALO BIO
(CS3025) or the HALO Standard HE Filter (CS3022). When configured with either of these filters, the HALO half
masks are approved and may be used with either the Standard Exhalation Valve Cover or the BIO Exhalation Valve
Cover.
The CS3038 Steri-Plus Exhalation Filter Case and the CS3039 Steri-Plus Exhalation Filter shall only be used in
combination with a HALO Half Mask fitted with the PAF-1111 Standard Exhalation Valve Cover. The Steri-Plus
Exhalation Filter shall NOT be used with the Head Cover. Note: The HALO Exhalation Filter does not provide or
contribute to the system’s respiratory protection. An HE Filter (CS3022 or CS3025) must be used.
The CS3027 HALO BIO Exhalation Filter shall only be used in combination with a HALO Half Mask fitted with the
CS3026 HALO BIO Exhalation Valve Cover. The HALO BIO Exhalation Filter can be used with or without the Head
Cover. Note: The HALO BIO Exhalation Filter does not provide or contribute to the system’s respiratory protection.
An HE Filter (CS3022 or CS3025) must be used.
Ensure that either the Standard Exhalation Valve Cover or BIO Exhalation Valve Cover (as applicable for the
intended configuration) is installed prior to use.
7. Limitations of Use
Use this Respirator strictly in accordance with all instructions in these user instructions and NIOSH Approval Labels.
Never modify or alter this product.
Do not remove the Respirator until you have left the contaminated area
,
unless you have pressing health reasons to do so (for instance you are experiencing dizziness and
believe removing the respirator while you leave the contaminated area may help).
Only suitable for use by clean-shaven personnel. Facial hair under the seal reduces protection and is not
permitted.
Note: Half Mask variants of CleanSpace do not protect your eyes. In conditions that may damage or
irritate eyes, use protective eyewear or a full-face variant of CleanSpace.
Only use your respirator with the parts and accessories listed on the Approval Label.
Do not use the respirator unless it is powered and running normally.
Do not use the respirator while it is being charged via the AC adaptor.
Do not use in airborne contaminant concentrations above those specified in your national regulations.
Do not use for respiratory protection against unknown atmospheric contaminants or when concentrations
of contaminants are unknown or immediately dangerous to life or health (IDLH).
Do not use in oxygen deficient or oxygen enriched atmospheres. Do not use in flammable or explosive
environments.
Only for use by trained personnel.
Filters need to be changed regularly. The frequency of change depends on use and the concentration of
contaminants in the atmosphere.
Do not use for escape purposes. National regulations may impose specific limitations on the use of filters
depending on the filter class and the facemask used.
LEAVE THE CONTAMINATED AREA IMMEDIATELY IF:
respirator warning lights and/or sounds activate for low battery or blocked filter
any part of the respirator is damaged
air flow into the mask decreases or stops
breathing becomes difficult or increased resistance occurs
you feel dizzy or your airway is irritated
you can taste or smell contaminants.
Your respirator is suitable for use in the following atmospheric conditions:
Temperature: 14°F to 113°F (-10°C to 45°C).
Relative humidity: 0 to 90% non-condensing.
The respirator will stop functioning if its internal temperature rises above 140°F (60°C) or falls below 14°F (-10°C).
If the respirator has been used in an area that has caused it to become contaminated with a substance requiring
special decontamination procedures it should be placed in a suitable container and sealed until it can be
decontaminated.
Summary of Contents for CS302
Page 8: ...8 Figure 1 System Components 9 System Components...
Page 46: ...46 2 1 LED CleanSpace HALO 3 1 Steri Plus HALO BIO CS3039 CS3027 IPA...
Page 55: ...55 PAF 0025 PortaCount S005 7174 PortaCount 22 PAPR CleanSpace HALO OSHA 1901 134 NIOSHI...
Page 57: ...57 13 CleanSpace HALO 5 1 HEPA HEPA 18 HEPA CleanSpace HALO 3 LED 19 2 20 C 1 2...
Page 59: ...59 CleanSpace CleanSpace HALO 3 5 5 8 6 9 4...
Page 60: ...60 7 2 FRONT 2 9...
Page 61: ...61 2 HALO OSHA 1910 134 Steri Plus Steri Plus Steri Plus 11 11 A B 12 12 10...
Page 62: ...62 13 13 14 15 16 17 18 19 1...
Page 63: ...63 20 CleanSpace HALO 5 HALO BIO CS3024 HALO BIO 14 CleanSpace HALO 21...
Page 64: ...64 PAF 1009 22 23 2 6 STERI PLUS PAF 1111 22 23...
Page 66: ...66 HALO BIO CS3029 HALO BIO HALO BIO 2 2 2 HALO BIO HALO BIO HALO BIO HALO BIO...
Page 67: ...67 15 CleanSpace HALO 6 1 HEPA HEPA 18 CleanSpace HALO 3 LED 19...
Page 69: ...69 3 LED 19 4 HEPA CleanSpace HALO 5 CleanSpace Technology...
Page 70: ...70 5 10 6 CleanSpace PAPR 4...
Page 71: ...71 2 1...
Page 72: ...72 CleanSpace CleanSpace 16 1 2 3 17 4 5 6 a b c d e f...
Page 73: ...73 g h 7 9 28 28 10 3 17 CleanSpace HALO 3 4 4 3 1 2 3 3 CleanSpace HALO 18...
Page 74: ...74 CleanSpace 1 2 2 1 LED 1 15 CS3027 HALO BIO CS3039 Steri Plus...
Page 82: ...82 2 122 F 50 C 2...
Page 83: ...83 HEPA CleanSpace HALO CleanSpace 21 CleanSpace HALO 36 F 20 C 13 22...
Page 84: ...84 PAF 0025 PortaCount S005 7174 PortaCount 1 TSI PortaCount CleanSpace TSI PortaCount...
Page 85: ...85 CleanSpace 1000 1000 1000 CleanSpace 25 23 HALO HALO BIO...