CleanSpace Respirators USER INSTRUCTIONS
30
English
English
Filters
–
For Particulates
Product Code
Description
PAF-0037
Particulate Filter P3 / TM3 P SL R High Capacity
PAF-0043
Particulate Filter P3
–
Replacement Pads for Combined Filters PAF-0046 and PAF-0047
–
3 Pk
(Australia only)
PAF-0053
Particulate Filter P3
–
Replacement Pads for Combined Filters PAF-0046 and PAF-0047
–
8 Pk with
Honeycomb Lid (Australia only)
Combined Filters
–
For Gases & Particulates
Product Code
Description
PAF-0038
Filter Adaptor - all large-case filters (PAF-0037, PAF-0046, PAF-0047, PAF-0050, PAF-0051)
PAF-0046
Combined Filter A1P3 (Australia)
PAF-0047
Combined Filter ABE1P3 (Australia)
PAF-0050
Combined Filter TM3 A1 P SL R (Europe)
PAF-0051
Combined Filter TM3 ABE1 P SL R (Europe)
Pre-Filters and Coveralls
Product Code
Description
PAF-0036
Particulate Pre-Filter (Standard)
PAF-0057
Particulate Pre-Filter (Large Case Filters)
PAF-0058
Particulate Pre-Filter and Coverall (Standard)
NOTIFIED BODIES
Respiratory Protection:
SAI Global Assurance Services Limited (2056)
PO Box 6236 Milton Keynes MK1 9E
IECEx
TestSafe Australia (IECEx TSA 13.0024X)
PO Box 592
Richmond NSW 2753 Australia
ATEX
Intertek Testing & Certification Limited (ITS14ATEX27939X)
Cleeve Road, Leatherhead, Surrey, KT22 7SB
United Kingdom
17.
Specifications
Air Flow
Manufacturers minimum design flow: 120 litre/minute
Breath-responsive, with max inflow to mask 120
–
200 litre per minute, dependant on altitude,
filter and battery condition.
Operating
Temperature Range
-10°C to 45°C.
The motor will shut down if the temperature of the battery pack rises above
60°C or falls below -
10°C
Operating Humidity
Range
Zero to 90%, non-condensing
Operating Altitude
Range
Approximately sea level to 1200m
Charging
Temperature Range
0°C to 35°C
Below 0°C and above 35°C the battery may not accept charge
Storage Conditions
Short term storage under 30 days:
Out of direct sunlight, in a clean, dry environment (30% - 50% RH), -10°C to 35°C.
To maintain the integrity of the internal battery, the respirator must be stored under the
following conditions when it will not be used for longer than 1 month
Long term storage (> 30 days):
Out of direct sunlight, in a clean, dry environment (30% - 50% RH), 18°C to 28°C.
Shelf Life (when
stored as specified)
We recommend to charge the battery every 6 months if the device is not in use.
Particulate Filters: 3 years