INSTALLING THE CLEAR COMFORT
MANIFOLD INJECTION
AIR FLOW METER
1. Determine your variable speed setting and run your pump (2,400
RPM or higher).
2. Disconnect the blue Air Tubing from the Check Valve (between the
Manifold and Check Valve)
3. Connect blue Air Tubing to the Flow Meter.
4. Adjust the Manifold’s 3-way valve to increase/decrease pressure until
the Flow Meter reads 5 - 7 LPM.
Note:
If RPM on variable speed
pump is altered, readjust air suction.
5. When adjusted to 5 - 7 LPM, disconnect the flow meter and
reconnect Air Tubing to the Check Valve. .
Figure 15: Adjusting 3-Way Valve
Water Out
Water In
5 - 7
LPM
From CCW100 System
To Venturi
From CCW100 System
To Venturi
Figure 14: Air Flow Meter