13
FieldShield FLATdrop
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018957 Rev C - July 2022
Note: DO NOT assemble the connector prior to pulling/placing fiber.
When placing a FLATdrop with an assembly (MPO or Single-Fiber) cables be sure to utilize the pulling tool. Failure to do so
could damage the assembly and render the cable useless.
First, remove cable ties from corrugated tube. Then, starting at the FLEXconnector end of tubing, unwrap the tubing to
expose the FLEXConnector and then
gently
pull the assembly free from the tubing. Do not yank it from the tubing.
Ship along connector
pieces will be tied to the
individual drops
MPO and Single-Fiber
Begin removing corrugated
tubing at end closest to the flat
drop (over the FLEXconnector)
The FS-PROTECT-TOOL can be used to protect the YOURx breakout during deployment, when a pulling line is
not required.
FS-PROTECT-YOURX