15
FieldShield FLATdrop
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 018957 Rev C - July 2022
Pulling SFF Single-fiber assemblies using the Pulling Sock
1.
The SFF assembly will feed into the pulling sock. If nec
-
essary, clean up the end of the pulling sock with a pair of
snips or a side-cutter.
You are now ready to pull the SFF to its desired location. Tie the pulling device to the loop on the end of the sock.
When you have reached to desired location, remove the pulling sock by pushing up on the back end of the sock to release
the compression.
Note:
Do not attempt yank it out of the pulling sock or fiber damage may occur.
2.
Insert the end of the SFF into the pulling sock, pushing the
sock onto the pre-terminated end.
3.
Continue feeding the sock onto the cable until it reached
the end of the pulling sock. When removing the sock, re
-
member to push up from the back end of the sock instead
of attempting to pull it off.