Installing a Cross-Connect Panel
The FAC 400 cabinet supports the following cross-connect option:
• 300-pair panel (2:1, 200 subscriber/100 equipment pairs).
The cross-connect systems are arranged in 50-pair blocks as shown below. Equipment-side blocks have dead pairs at the
25th and 50th positions.
This section describes how to install a cross-connect panel into a cabinet not factory-equipped with the option. The
cross-connect panel resides in the side compartment, behind the protection blocks.
For cabinets already in service, installing a cross-connect panel will affect service to subscribers, because the cross-connect
panel sits inline between the cabinet’s copper line protection and the OSP (‘Subscriber’ side) cables. Clearfield recommends
performing the installation during a maintenance window to minimize the service impact.
Note:
All Clearfield equipment uses a ‘dead pair’ scheme, where the 25th pair in each 25-pair cable group is unterminated
and not used (dead).
300-pair cross-connect panel
150-pair cross-connect panel