103
FieldSmart
®
Fiber Active Cabinet (FAC) 400
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 020419 REV A - Feb 2019
To install a cross-connect panel
Unpack the cross-connect panel from the shipping packaging.
Open the cabinet’s side door.
Position the cross-connect panel against the mounting fixture, with the cables toward the back. Align the eight
mounting holes in the cross-connect panel with the counterpart holes in the mounting fixture.
Secure the cross-connect panel to the rack using the eight supplied mounting screws from the installation kit.
Terminate the cross-connect interface cables as follows:
• Mate the equipment-side cables to the appropriate protection block interface cables (MS2 connectors).
• Mate the subscriber-side cables to the appropriate OSP interface cables (MS2 or 710 connectors).
Dress and secure all cables with tie-wraps.
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6: