129
FieldSmart
®
Fiber Active Cabinet (FAC) 400
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 020419 REV A - Feb 2019
b. Bottom hinge:
Press the pin lever down and rotate it away from the
cradle.
Release the hinge pins from the hinge pin channels:
a. Top hinge:
Press down on the pin lever until the pin slides free from the channel.
b. Bottom hinge:
Lift up on the pin lever until the pin slides free from the channel.
Insert the new door into the door frame. Align the door hinge knuckles with the counterpart hinge knuckles on
the door frame.
Engage the hinge pins to secure the door in place as follows:
a. Top hinge:
Lift up on the pin lever until the pin slides completely into the pin channel.
b. Bottom hinge:
Press down on the pin lever until the pin slides completely into the pin channel.
c.
Rotate the pin levers into the cradles to secure the hinges.
Attach the wind brace bracket to the inside of the door using the three nuts removed from the previous door.
Attach the ground strap to the door using the hex nut removed from the previous door.
For a heat exchanger door, connect the heat
exchanger power (and alarm) cable to the cabinet
wiring:
a.
Locate the heat exchanger cable on the inside of
the door.
b.
Route and connect the heat exchanger cable to
the cabinet extension cable.
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Step 8: