FieldSmart
®
Fiber Active Cabinet (FAC) 400
Installation Manual
_________________________________________________________
Proprietary Information: Not for use or disclosure except by written agreement with Clearfield.
44
•
Use the Clearfield wall-mount kit to provide the mounting fixture and conduit entry locations.
•
The Clearfield wall-mount kit provides assembly hardware for a wall or wooden H-frame, however you must provide the
hardware to attach the mounting fixture, as appropriate for your site requirements. For example, attaching the
fixture to a concrete wall requires different hardware (anchors). Follow local codes and practices to supply the
required mounting hardware.
• Use cold-shrink tubing on the conduit entry ducts to seal the conduit entry.
•
Use 4-inch conduit (maximum) for outside plant cables. See figure for entry locations.
•
Use 2.5-inch conduit (maximum) for AC cable. See figure for entry location.
• Include pull cords in all cable conduits.
•
For H-frames, Clearfield recommends using (2) 4” x 4” x 4.0’ horizontal members on the top and (3) 4” x 4” x 4.0’
horizontal members on the bottom to support the fixture, positioned for the following mounting hardware locations:
Horizontal Spacing
Vertical Spacing
Top bracket:
11 inches on centers
To bottom bracket’s upper hole set:
Single battery base: 54.56 inches on centers
Dual battery base: 65.87 inches on centers
Bottom bracket:
28 inches on centers
To bottom bracket’s lower hole set:
Single battery base: 68.56 inches on centers
Dual battery base: 79.87 inches on centers