Cabinet Features
Standard features of the FAC 400 cabinet include:
Enclosure Design
• Environmentally sealed design protects from dust and water intrusion
• GR-487 compliant and UL-67 spec
• Environmentally rated from -40C to +46C (per GR-487)
Equipment Support
• 19-inch equipment rack provides 4 RU of mounting space
•
Mechanical support for fiber and copper plant terminations
• Modular, scalable copper line protection (50-pair block increments, 300 pairs maximum)
• Door-mounted 300W heat exchanger
Power (Local)
Standard features for the local power configuration include:
• 240 VAC load center (ETL-listed); 30 Amp capacity
• AC main/service disconnect breaker
• AC surge suppressor
• Duplex convenience outlet (GFCI protected)
•
FAC 400 Power Hub compact DC rectifier shelf
• Fuse-protected DC supply to equipment
• Low voltage DC disconnect (-42 VDC)
• Battery backup in separate vented compartment
• Up to 62 Ah battery reserve capacity (breaker-protected); up to 124 Ah capacity with second-string riser option