81
FieldSmart
®
Fiber Active Cabinet (FAC) 400
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 020419 REV A - Feb 2019
Splicing Metallic Cables
Secure the OSP cable to the cabinet tie bars with cable ties.
Remove the core wrap from around the bundled copper pairs, then install binder group identification labels
on each 25-pair group.
If splicing shall be performed at a later time, make sure the cable arrangement allows the door to close.
Take care to not violate the cable bend radius requirements.
Step 4:
Step 5:
Step 6:
Mate the outside plant (OSP) cables to the equipment interface cables using MS2 connectors. Interface cables on the OSP
side (‘Subscriber’ side) of the protection blocks or optional cross-connect panel are factory terminated with MS2 or 710
connectors. You must install counterpart MS2 or 710 connectors on each 25-pair group of OSP cables before mating.
Note:
Clearfield equipment uses a ‘dead pair’ scheme, where the 25th pair in each 25-pair cable group is unterminated and
not used (dead).
To splice the metallic cables
Open the cabinet’s side door.
Segregate the bundled pairs from the OSP cable into 25-pair groups.
Terminate MS2 or 710 connectors onto the ends of each 25-pair group per local practice.
Remove all cable ties securing the cabinet interface cables to tie bars and remove the protective covers from
the connectors.
For each 25-pair group, mate the OSP and equipment interface cable connectors together using the
appropriate mating clamps.
Repeat Steps 2 through 5 for each remaining OSP cable.
Dress and secure the spliced cables to the tie bars with cable ties.
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7: