61
FieldSmart
®
Fiber Active Cabinet (FAC) 900
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 020420 REV B - April 2019
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Operating a Cabinet or Expansion Module Door
Cabinet Doors
The cabinet has hinged front and side doors, each equipped with two telco hex-pin latches and a padlock hasp for security.
Open and close doors using a Clearfield -supplied telco hex key.
Each door is equipped with an alarm switch that monitors the position of the door. When a door on an in-service cabinet
or EXM is opened, an intrusion alarm reports through the equipment. Pull the switch plunger to disable the alarm reporting
while you are working on the cabinet or EXM. The alarm switch is located at the upper right corner of the door frame.
To open a cabinet or EXM door
Insert the telco hex key into the door's upper hex-pin latch.
Turn the key counter-clockwise to disengage the latch.
Repeat Steps 1 and 2 to disengage the lower latch.
Swing the door open until the wind brace engages.
On a powered cabinet, pull the alarm switch plunger to disable reporting of the intrusion alarm.
Note:
Do not rotate the switch plunger. Rotating the plunger may damage the switch.