Fiber routing in the 576- port cabinet is
done in the same fashion as the 288 port,
with the exception that splitter outputs
from either side of the cabinet can reach
distribution and feeder ports on either
side of the cabinet.
576 PON Cabinet
288 PON Cabinet
The 288, 576 and 1152 PON Cabinets will allow up to 2 staging plates in each staging area at the top of the cabinet. One
staging plate can be installed with the foam cradle in place, or you can remove the foam cradle and replace with the foam
strips on each end of the staging plate. This will allow two staging plates to fit in each staging area.
Choose your desired port to connect the splitter leg and reference the designation card. Each port will have a color,
corresponding to the radius spool that the splitter leg must route over to properly take up the slack before connection.
Splitter Leg
Routing
Single Staging Plate
Two Staging Plates