1
Field Installable FlexConnector for Generic Cable
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net
Manual 019609 REV A - Jul 2018
Step 3
:
Use scissors to snip orange
pull cord.
Step 1
:
Measure cable to YOURx
length (14 inches) and mark outer
cable sheath.
Figure 1
Figure 2
Step 4
:
Pull orange pull cord to split
outer cable sheath and expose 3mm
breakout.
Figure 4
Figure 3
Step 2
:
Use rotary cutter to cut outer
cable sheath and expose orange pull
cord.
Step 5
:
Snip strength member strands
and
save for later use
.
Figure 5
Step 6
:
Pull aside the kevlar strands.
Figure 6
Step 7
:
Slide
smallest, 5/16” x 3” long
(004458) section of heat shrink over
breakout and onto jacketed fiber for
later use.
Figure 7
Step 8
:
Slide
medium, 1/2” x 2 1/4”
long (004644) length of heat shrink
over breakout and onto jacketed fiber
for later use.
Figure 8
Step 9
:
Bend one of the strength
member strands to form a fish-eye
loop.
Figure 9
Installing the Field Installable FlexConnector