background image

8) 

Plumb  the  Door  and  remaining  Wall  Receiver.  Through  the  oversize  holes  in  the  Door  jamb 

drill through the Wall Receiver frame and into the wall stud using a 3.0 mm drill bit

 

9) 

Secure the Wall Receiver to the wall using 

the No.6x 38mm stainless steel screws.

 

 

10) Cap

 t

he oversize holes in the door Jamb using the 

9mm plas c plugs

 

13

From the inside using a 3.0mm drill  bit; drill through the ver cal sec ons of the Door  into the Wall 

Receivers.  Fix  the  Door  to  the  Wall  Receivers.  You  must  have  a  minimum  of  10mm  overlay  and  the 
holes  must  be  drilled  no  less  than  5mm  from  the  edge  of  the  ver cal  aluminium  sec ons.  Secure  in 
place using the 6 gauge x 10mm screws. 

 

 

Secure the Door Set  (All Screw fixings are made from the Inside) 

Summary of Contents for Alcove

Page 1: ...Please read these Instruc ons carefully May 2018 Installa on Instruc ons Alcove ...

Page 2: ... the Door and Return Installa on Components Handle where applicable Drip Seal 1m Cleaning Towele e White showers only No 6 x 10mm screw No 6 x 38mm screw Qty 6 Screw Cap Qty 6 Drill Spirit level Tape Measure Screw Driver No 1 Sq drive Tools Required Caulking Gun Masking tape Pencil Cleaning Cloth Tube of NG Silicone Colour matched to shower A C B 9mm Plug Qty 3 ...

Page 3: ... system can also be used 4 Secure the Wall Receiver to the wall using the No 6 x 38mm stainless steel screws NB As a precau on apply silicone sealant into the drilled holes 1 Determine which side the Door is to be hung Posi on one of the Door Wall Receivers hard against the inside edge of the tray up stand NOTE If the shower walls are to be tiled the Wall Re ceivers must be installed to the Water ...

Page 4: ...lock this will assist in suppor ng the door during installa on and se ng the correct clear ance from the sill Li the Door assembly with the Wall Receiver a ached onto the shower step and slide into the Door Wall Receiver already installed 6 Side the remaining Door Wall Receiver onto the Door Assembly Door ...

Page 5: ...0 Cap the oversize holes in the door Jamb using the 9mm plas c plugs 13 From the inside using a 3 0mm drill bit drill through the ver cal sec ons of the Door into the Wall Receivers Fix the Door to the Wall Receivers You must have a minimum of 10mm overlay and the holes must be drilled no less than 5mm from the edge of the ver cal aluminium sec ons Secure in place using the 6 gauge x 10mm screws S...

Page 6: ...move the door se ng block Notch under Door Magnet profile 18 Fit the Drip Seals to the glass door 14 Secure in place using the 6 gauge x 10mm screws Adjust the Door Drip Seals 17 The Drip seal is supplied in a 1m length this will need to be cut to the desired lengths for each side of the pivot The open ing side Drip seal will also need to be notched to fit under the door magnet profile Make the Notch...

Page 7: ...l Receivers and Wall Liner Note MASKING the area to be Sealed will result in a superior finish 19 Cover Trim selected models only The Cover Trim is provided to cover the exposed ver cal edge of the wall liner and is the final step of the installa on For some installa ons the Cover trims may require cu ng to length To fit the Cover trim apply small ver cal beads of silicone down the Wall Receiver and ...