Appendices
~ Appendix E: Serial Commands
108
Technical Services Group
~ 1-800-283-5936 (USA) ~ 1-801-974-3760
GATE - Gate Status
This command reports the gate status of mics. This command is read only.
Command form: DEVICE
GATE
Argument details
Name
Description
Device
0–7 or * to select all units
GATE
Command form
The command will return the gate status of mic inputs 1–8 in hexadecimal.
Example:
GHOLD- Gate Hold Time Adjust
This command selects/reports the setting of hold time.
Command form: DEVICE
GHOLD
<Channel> [Value]
Argument details
Name
Description
Units
Device
0–7 or * to select all units
GHOLD
Command form
Channel
See Groups and Channels, page 97
Value
0.10-8.00 S
Null to return the current hold time
Example:
#50 GHOLD 1 .3
On XAP 800 unit 0 (
#50
), the hold time (
GHOLD
)
for mic channel
1
is 300ms (
.3
).
If
Hex # returned
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Mic 8
Mic 7
Mic 6
Mic 5
Mic 4
Mic 3
Mic 2
Mic 1
Mics 1 and 2 are gated on
0 3
0
0
0
0
0
0
1
1
Mics 1 and 3 are gated on
0 5
0
0
0
0
0
1
0
1
Mics 1, 4, and 7 are gated on
4 9
0
1
0
0
1
0
0
1
Mics 3–6 and 8 are gated on
B C
1
0
1
1
1
1
0
0
Hexadecimal Description
First digit
Second digit
Summary of Contents for XAP 800
Page 1: ...XAP 800 Audio Conferencing System Installation Operation Manual ...
Page 6: ...vi Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 26: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 90: ...84 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 135: ...129 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 Appendices Appendix F Warranty ...