113
Technical Services Group
~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
LVLREPORT - Level Report
This command selects level status reporting.
Command form: DEVICE
LVLREPORT
<Channel> <Group> [Position] [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
LVLREPORT
Command form
Channel
See Groups and Channels, page 97
Group
See Groups and Channels, page 97
Position
See Meter Type Definitions, page 98
Value
0 = Off (Delete level from list of levels to be reported)
1 =On (Add specified level to list of levels to be reported)
2 = Toggle
Example:
#52 LVLREPORT 8 L I 1
On XAP 800 unit 2 (
#52
), the level
(
LVLREPORT
) of line level (
L
) input
8
at the input stage (
I
) is to be added (
1
) to
the report.
LVLRRATE - Level Report Rate
Sets the level report rate for the unit and activates/deactivates level repeating.
Command form: DEVICE
LVLRRATE
[Value]
Argument details
Name
Description
Units
Device
0–7 or * to select all units
LVLRRATE
Command form
Value
0 = Turn off reporting but leave current list
1 = Turn off reporting and clear the list
50 to 1000 = Set Rate (1 meter every x ms)
ms
Null to return current value
Example:
#53 LVLRRATE 100
On XAP 800 unit 3 (
#53
), the level report rate
(
LVLRRATE
) is set to
100
ms.
Summary of Contents for XAP 800
Page 1: ...XAP 800 Audio Conferencing System Installation Operation Manual ...
Page 6: ...vi Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 26: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 90: ...84 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 135: ...129 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 Appendices Appendix F Warranty ...