119
Technical Services Group
~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
MUTE - Mute
This command selects/reports the setting of mute on input, output or processing
channels.
Command form: DEVICE
MUTE
<Channel> <Group> [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
MUTE
Command form
Channel
See Groups and Channels, page 97
Group
I, O, M, P, L
Value
0 = Off, 1 = On, 2 = Toggle, Null = current mode
Example:
#51 MUTE 2 M 1
On XAP 800 unit 1 (
#51
), the mute (
MUTE
) for
mic (
M
) channel
2
is on (
1
).
NCD - Noise Cancellation Depth
This command selects/reports the noise cancellation amount for each mic channel.
Command form: DEVICE
NCD
<Channel> [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
NCD
Command form
Channel 1–8
(select
mic
input)
Value
6 - 15 (set noise cancellation from 6 to 15dB),
Null to return the current mode
Example:
#52 NCD 1 9
On XAP 800 unit 2 (
#52
), the noise cancellation depth
(
NCD
) of mic channel
1
is
9
dB.
NCSEL - Noise Cancellation Select
This command selects/reports the Noise Cancellation for each mic channel.
Command form: DEVICE
NCSEL
<Channel> <Value>
Argument details
Name
Description
Device
0–7 or * to select all units
NCSEL
Command form
Channel 1–8
(select
mic
input)
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#53 NCSEL 2 1
On XAP 800 unit 3 (
#53
), the noise cancellation
(
NCSEL
) for mic channel
2
is enabled (
1
).
Noise cancellation must
be enabled for this
command to have any
effect on audio quality.
✍ ✍
Summary of Contents for XAP 800
Page 1: ...XAP 800 Audio Conferencing System Installation Operation Manual ...
Page 6: ...vi Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 26: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 90: ...84 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 135: ...129 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 Appendices Appendix F Warranty ...