126
Technical Services Group
~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
SIGTOUT - Signal Generator Time Out
Sets the signal generator time out for the unit.
Command form: DEVICE
SIGTOUT
[Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SIGGEN
Command
Value
0 = Off, 1–30 = Set time out minutes, Null = Current rate
Example:
#57 SIGTOUT 15
On XAP 800 unit 7 (
#57
), the signal generator
time out (
SIGTOUT
) is set to
15
minutes.
SLVL - Speech Level Control Enable/Disable
This command selects/reports the setting of speech level control for a microphone.
Command form: DEVICE SLVL <Channel> [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SLVL
Command
Channel
1–8 (select mic input)
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current mode
Example:
#50 SLVL 2 M 1
On XAp 400 unit 0 (
#50
), the speech leveler for mic
(
M
) channel
2
is set to on (
1
).
STRING - String Execution
This command sends the specified string out the serial port.
Command form: DEVICE
STRING
[ID]
Argument details
Name
Description
Device
0–7 or * to select all units
STRING
Command
ID
0 – 7
Null to query last string in text
Example:
#51 STRING 3
On XAP 800 unit 1 (
#51
), the
STRING
programmed
into location
3
will be sent out the RS-232 port.
The serial command to
create a string is
PRGSTRING (Program
String). See page 122.
✍ ✍
Summary of Contents for XAP 800
Page 1: ...XAP 800 Audio Conferencing System Installation Operation Manual ...
Page 6: ...vi Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 26: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 90: ...84 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 135: ...129 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 Appendices Appendix F Warranty ...