25
Technical Services Group
~ 1-800-283-5936 (USA) ~ 1-801-974-3760
System Configuration
~ Site Setup
Configuring Unit Properties
Using the Unit Properties window, you can configure the unit‘s communication and
security properties in addition to general unit properties such as name, type, and
country code. The Unit Properties window automatically opens when you manually
add a unit to the site. You can also right-click the unit icon in the site pane and click
Unit Properties.
To configure Unit Properties
1.
Type a descriptive
Unit Name
in the space provided. The Unit Identification
and Firmware Version will be supplied by the unit when a connection is made.
2.
If you have already established a connection with the site, the Device
ID will be assigned. Otherwise, select the
Device ID
that matches the ID you
assigned the unit via the front-panel LCD menu.
Device IDs ensure the software will sync up with the proper unit when there
are multiple XAP 800s on a network.
3.
Select the
Unit Type
(default is slave). See page 12 for more information.
4.
Select an input, output, or processing channel to be the
Default Meter
on
the front panel meter LED when a channel is not specifically selected.
5.
Select the
Meter Refresh Rate
, which determines how quickly the XAP 800
updates meter information (default is 100ms; range is 50–1000ms).
6.
Click the
Comm
tab. The Baud Rate and Flow Control settings are supplied
by the unit when a connection is made. These settings are changed using the
Site Properties window (see page 23).
7.
Set the
Serial Echo
(default On) and the
Serial Mode
(default Text).
Serial Echo echos back commands sent over the XAP 800 network. The serial
mode determines the format in which the commands return—text or binary.
The mode defaults to Binary when G-Ware is connected and to Text when
disconnected. Contact technical support for instructions on using Binary
mode.
Figure 3.11. Unit icons in Site
Pane with Unit menu displayed
Figure 3.12. Unit Properties, General tab
Figure 3.13. Unit Properties Comm tab
Summary of Contents for XAP 800
Page 1: ...XAP 800 Audio Conferencing System Installation Operation Manual ...
Page 6: ...vi Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 26: ...20 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 90: ...84 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 ...
Page 135: ...129 Technical Services Group 1 800 283 5936 USA 1 801 974 3760 Appendices Appendix F Warranty ...