END WALL and END PANEL INSTALLATION
The end walls for the greenhouse are installed
before
the main cover is attached. The steps to install the end
walls for the greenhouse include the following:
1. Measure, assemble, and temporarily install end wall
frame tube (bottom). (See End Wall Diagram at the
back of these instructions.)
2. Mark rough door opening on bottom frame tube,
remove tube, insert tube into the pocket at the
bottom of the end wall panel (front only), and
reattach bottom tube to end rafter.
3. Install doorframe tubes, attach end panels to end
rafters, and remove excess panel material (if
desired).
INSTALL END WALL FRAMING (Front and Back)
Consult the End Wall Diagram at the back of these
instructions for the location of the brackets used to
connect the frame members to the end rafter.
DOOR LOCATION:
The following procedure installs the
single door in the center of the end wall.
Accessories/Equipment:
Typically, items such as vents
and exhaust fans are installed in the end walls. Consult
the instructions for these items to properly space the end
wall frame members (if equipped), or to purchase
additional bracing and framing to install an item.
These instructions address the assembly of the
greenhouse. They
DO NOT
account for the installation
of any items included in equipment packs.
Continue with the following steps to assemble the end
wall frame tube (bottom).
1. Install a band clamp around each ground post of the
front, end rafter assembly.
NOTE:
Verify that the correct band clamp is used for the
ground post and position the clamp as shown above.
2. Locate the square metal tubing for the bottom frame
member of the end wall. The bottom frame member
consists of two (2) long 99" plain sections of square
pipe, joined using a square tube middle coupler, and
cut to the correct length (if needed).
NOTE:
When cutting the bottom end wall frame tube to
the proper length, remember to
subtract 1 3/4" for each
of the 104074 square to round tube brackets
, which
are attached to the ends of the frame tube.
Band clamp
Ground Post
End Frame Tube
Rafter
Leg Pipe
104074 Bracket
Visit www.ClearSpan.com for additional products and customer assistance.