background image

Cover has been removed to show the cover conduit that 
the strap wraps around. 

 

 

 

NOTE:

 Verify that the cover is centered side-to-side 

before attaching the straps. 

 

13.  Repeat the steps for the remaining D-Rings and 

straps. 

 

NOTE:

 All D-Rings and strap assemblies are installed on 

the same side of the greenhouse. Ratchets are attached 
directly across from the D-Rings and straps on the same 
rafter assembly.

 

 
14.  Move to the other side of the greenhouse and attach 

the ratchets to the rafter legs. Use the main cover 
conduit as a guide when attaching the ratchets to 
the rafter legs at the proper height. 

 
15.  As previously described, make a slit in the cover 

conduit pocket and insert a section of strap through 
the slit and around the cover conduit. 

 

 

  
16.  Thread the strap into the ratchet and slightly tighten.  

 
NOTE:

 It may be necessary to remove excess strap if it 

binds up in the ratchet. 
 

 

 

The above diagram is used for illustration only. It shows 
a different but similar greenhouse frame. 

 

17.  Repeat the steps for the remaining ratchets. 
 
18.  Using additional help (if needed) tighten the main 

cover beginning with the ratchets along the side of 
the greenhouse frame. 

 
19.  After the side ratchets are tightened, return to the 

front and back end wall ratchets and tighten those. 

 

NOTE:

 Loosen the ratchets if needed to remove excess 

strap. If the main cover is not centered as desired, the D-
Rings and strap assemblies can be reposition (higher or 
lower) as needed and the main cover retightened. 
 
20.  Fold the skirt of main cover down and over the 

ratchets and D-Ring Straps to complete the 
installation of the main cover.  

 
21.  Continue by reading the 

Greenhouse Care and 

Maintenance

 information that follows. 

 

 

 

 

Cover Conduit

Visit www.ClearSpan.com for additional products and customer assistance.

21 of 24

Summary of Contents for 103557

Page 1: ... Style 16 Wide x 8 High Pro Greenhouse Round Style ClearSpan All Rights Reserved Reproduction is prohibited without permission Revision date March 2006g Sku Numbers 104881 104882 103557 Diagram may show a different length ...

Page 2: ... determine whether your selected location is the best location Never erect the structure under power lines Identify whether underground cables and pipes are present before preparing the site or anchoring the structure Location should be away from structures that could cause snow to drift on or around the building Do not position the building in a place where large loads such as snow and ice large ...

Page 3: ... words and phrases below are common to most ClearSpan shelters and identify the different parts of the shelter Some are used in this document Others may not apply to this particular shelter These terms are used to describe the shipped parts and can also be found on the materials list spec sheets included with the shipment To aid in the assembly read through the following definitions before you beg...

Page 4: ...location and application Tape measure or measuring device Marker to mark locations on the pipes Variable speed drill and impact driver cordless with extra batteries works best Metal cutting saw Wrenches and impact socket set or an adjustable wrench Scissors utility knife tin snips Hammers and gloves Adjustable pliers and self locking pliers Ladders work platforms and other machinery for lifting de...

Page 5: ...onnector to the rafter and end wall frame Ground post shown above Baseboard is not used for all greenhouse models Diagram is for illustration only Fabric Clip is used to secure the end panels and roll up side panel if equipped to the cover conduit if needed It is secured using the Tek screw QH1330 Bracket Pictorial Parts Guide Not all parts are shown Visit www ClearSpan com for additional products...

Page 6: ...use frame with the same components Pro Greenhouse Frame Diagram 16 Wide Round End Rafter Purlin Inside Rafter Ground Post Strut Bottom Conduit for Frame End Clamp Visit www ClearSpan com for additional products and customer assistance 5 of 24 ...

Page 7: ...st ground post 3 Sting a line at least as long as the building from the first ground post at 90 NOTE A transit can be used to ensure an accurate 90 angle or the 3 4 5 rule can be used See the diagram below Using multiples of 3 4 5 such as 6 8 10 or 12 16 20 helps to maintain an accurate 90 angle 4 After squaring the position of the building measure the building length and drive the next corner gro...

Page 8: ... NOTE The end clamps must be positioned as shown in the photo that follows The pipe that is shown with the end clamp is installed in a later step 3 After slipping the clamps over the different rafter pipes insert the swaged end of the rafter pipes into the plain ends of the pipes to assemble the rafter NOTE The end clamps at the lower end of the rafter legs will sit on top of the ground posts when...

Page 9: ...rlins are part of the assembled frame and run perpendicular to the rafter assemblies Each purlin consists of 1 315 x 75 131S075 swaged pipes number is determined by shelter length and one 1 1 315 x XX 131P0XX plain pipe ATTENTION The XX represents the remaining length required to reach the end of the shelter Consult the Spec Sheet for part identification 1 Select the required pipe sections for one...

Page 10: ...at the measurements were made from when the purlin was pre marked 5 Insert the purlin pipe section through the top purlin clamp of the end rafter and through the cross clamp at the top of the middle or second rafter 6 Rotate the purlin pipe so that the first mark is visible near the clamp of the second rafter and position the plain end of the purlin flush with or slightly to the inside of the end ...

Page 11: ... or backward as needed to maintain this dimension 16 Repeat the above steps as needed to stand place and secure the remaining rafters to complete the frame assembly NOTE If the last rafter is plumb and the purlin extends beyond the end of the rafter cut the last section of purlin pipe to the required length DO NOT allow the purlin to extend beyond the end rafter Diagram may show a similar shelter ...

Page 12: ...5 struts are positioned between the end rafters and the first interior rafter on each side of the shelter See the previous diagrams Complete these steps to install the four 4 side struts 1 Locate one strut and position it between one end rafter leg and the leg of the first interior rafter as shown below 2 Place one band clamp around the rafter leg of the end rafter and attach one end of the strut ...

Page 13: ...alled 7 Complete the next procedure to anchor the assembled frame ANCHOR THE ASSEMBLED FRAME At this point in the assembly process anchor the assembled frame Once the frame assembly is anchored properly continue with these instructions You must anchor the shelter as described in the MUST READ document FAILING TO PROPERLY ANCHOR THE SHELTER WILL RESULT IN DAMAGE TO THE SHELTER AND CAN CAUSE PERSONA...

Page 14: ...e end walls Consult the instructions for these items to properly space the end wall frame members if equipped or to purchase additional bracing and framing to install an item These instructions address the assembly of the greenhouse They DO NOT account for the installation of any items included in equipment packs Continue with the following steps to assemble the end wall frame tube bottom 1 Instal...

Page 15: ...m as a guide mark the rough door opening for the pedestrian door 6 Repeat the steps for the back end wall ATTENTION The back end wall like the front is framed for the installation of the pedestrian door If you are not planning to install an optional pedestrian door in the back wall the vertical frame tubes for the doorframe can be cut and moved outward to align with the zippered end wall cover Thi...

Page 16: ...on near the top of the rafter pull the end panel up and over the top of the end rafter and secure it to the inside of the end rafter using fabric clips and Tek screws NOTE Do not remove the excess end panel material at this time 13 After attaching the end panel to the end rafter continue by attaching the doorframe tubes to the end wall bottom frame tube and end rafter ATTACH VERTICAL DOORFRAME TUB...

Page 17: ...e bracket to one end of the vertical frame member Use a 5 16 drill bit to drill a hole through the tube and attach the bracket to the tube using a nut and carriage bolt 9 With the 104074 square to round tube bracket attached to the top of the frame member above attach the frame member to the band clamp on the rafter Do not tighten at this time 10 Verify that the vertical end wall frame tube is plu...

Page 18: ...led front end wall For the following procedure the rough door opening is cut in the end panel and the material is wrapped around each frame member of the doorframe before the pedestrian door is installed Complete the following steps 1 Using the frame tubes of the door opening as a guide use a utility knife or scissors to cut through the end panel and remove the material from the opening where the ...

Page 19: ...ntal frame tube 6 With the door in position secure it to the doorframe tubes using Tek screws and fender washers inserted from the outside through the doorframe and into the doorframe tubes To better show the door and end wall framing the end panel is not shown in the above diagram 7 After the front end wall is completed repeat the procedure for the back end wall NOTE When inserting the end frame ...

Page 20: ...s for the cover conduit and assemble them as needed NOTE The cover conduit assemblies are identical to the purlins and frame conduit assembled earlier and attached to the frame These cover conduits are inserted into the pockets sewn into the main cover The conduits are used to tighten and secure the main cover 3 After assembling the cover conduits locate the main cover and unfold it on a clean smo...

Page 21: ... this time Diagram may show a slightly different application 10 Place the D Ring and straps on the ground next to the rafter they will be attached to The D Rings and straps are placed evenly along the same side of the frame In the above diagram D Rings and straps are attached on the rafters identified by the arrows 11 On the side where the D Rings and straps are located lift the cover skirt and cu...

Page 22: ...tly tighten NOTE It may be necessary to remove excess strap if it binds up in the ratchet The above diagram is used for illustration only It shows a different but similar greenhouse frame 17 Repeat the steps for the remaining ratchets 18 Using additional help if needed tighten the main cover beginning with the ratchets along the side of the greenhouse frame 19 After the side ratchets are tightened...

Page 23: ...objects that can accumulate on the greenhouse Use tools that will not damage the cover when removing debris Remove snow to prevent excess accumulation Use tools that will not damage the cover when removing snow Check the contents of the shelter to verify that nothing is touching the cover that could cause damage If the shelter is moved inspect all parts and connections before using Depending on th...

Page 24: ...ront and Back End Wall Frame Diagram 16 Round Pro 16 Center to Center 81 1 2 36 1 2 Inside rough door dimensions are shown Visit www ClearSpan com for additional products and customer assistance 23 of 24 ...

Page 25: ...Pro Greenhouse 16 Round Style 104881 16 W x 8 H x 16 L 104882 16 W x 8 H x 20 L 103557 16 W x 8 H x 24 L Visit www ClearSpan com for additional products and customer assistance 24 of 24 ...

Reviews: