Revision date: 05.13.10
Cable Installation
INSTALL AND TIGHTEN ALL CABLES
The diagram and inserts below identify the placement and proper way to attach the cable assemblies to the
frame.
After attaching all cables to the frame, tighten the turnbuckles.
Turnbuckles should be snug and not
overtightened.
Shorten cable if you are unable to tighten the turnbuckle to remove cable slack.
Cable
Ground Level
Frame length and design of your building may
differ from what is shown.
Secure the turnbuckle directly to the cable bracket
attached to each end rafter mounting bolt.
If necessary, use a bar or clamp to slightly bend
the bracket to allow the needed clearance to
install the jaw bolt of the turnbuckle.
Actual turnbuckle may differ.
Diagram shows the cables attached to the shackle
and the shackle secured to the eyebolt.
Thimble
Shackle