PTZ decoder and DVR address is not compatible.
•
When there are several decoders, please add 120 Ohm between the PTZ decoder
A/B cables furthest end to delete the reverberation or impedance matching. Otherwise
the PTZ control is not stable.
•
The distance is too far.
12. Motion detection function does not work.
There are following possibilities:
•
Period setup is not correct.
•
Motion detection zone setup is not correct.
•
Sensitivity is too low.
•
For some versions, there is hardware limit.
13. Can not log in client-end or web.
There are following possibilities:
•
For Windows 98 or Windows ME user, please update your system to Windows 2000
sp4. Or you can install client-end software of lower version. Please note right now,
our DVR is not compatible with Windows VISTA control.
•
ActiveX control has been disabled.
•
No dx8.1 or higher. Please upgrade display card driver.
•
Network connection error.
•
Network setup error.
•
Password or user name is invalid.
•
Client-end is not compatible with DVR program.
14. There is only mosaic no video when preview or playback video file remotely.
There are following possibilities:
•
Network fluency is not good.
•
Client-end resources are limit.
•
There is multiple-cast group setup in DVR. This mode can result in mosaic. Usually
we do not recommend this mode.
•
There is privacy mask or channel protection setup.
•
Current user has no right to monitor.
•
DVR local video output quality is not good.
15. Network connection is not stable.
There are following possibilities:
•
Network is not stable.
•
IP address conflict.
•
MAC address conflict.
•
PC or DVR network card is not good.
16. Burn error /USB back error.
There are following possibilities:
•
Burner and DVR are in the same data cable.
121