background image

 

ООО "Бассейн-Сервис" – продажа и монтаж оборудования для бассейнов.

 

Тел: 8 (800) 700-65-50

www.bassein-servis.ru

 

 

 

You can very easily raise the TDS level - IF YOU NEED TO. Remember, the TDS level always goes up whenever anything is 
added to the spa, and a reading at least 500 ppm may be obtained over a short period of time. The TDS level never goes 
down, so if you have to raise the TDS, it would be only for this one time or whenever you change the water in the spa. You 
may not have to raise the TDS because of the size of your spa. The unit is designed to handle 2,000 gallons of water easily. 
You would really only need to raise the TDS level if the spa was a large one and the purifier was unable to put the proper 
amount of copper-ions in the water.

 

To raise the TDS, you would need to add 1 ounce of regular salt to raise the TDS by 10 ppm per 500 gallons. Do not worry 
about turning the spa into salt water - the TDS of that is 33,000 ppm! Only add salt if necessary when you cannot obtain the 
desired copper-ion level. Low TDS levels is actually desirable.

 

The 

Clearwater Spa Purifier 

will work on any TDS level, however, a reading over 2,000 ppm should be lowered because 

more of an oxidizer will be required. To lower the TDS, partially drain the water and add fresh water. Chances are that if your 
TDS was over 2,000 ppm your water was cloudy often, or required a lot of chlorine or bromine.

 

 

COPPER LEVEL

 

Before installing the 

Clearwater Spa Purifier

, you should test the copper level. There may be a level of copper sulfate in the 

water from leached copper piping, or from a copper based algaecide. If the reading is over .10 ppm, corrections may have to 
be made. You want to have a proper balance of copper and silver ions in the water, so you need to find the source of the 
copper already in the water. Remember, this is not the same copper that is produced by the purifier. If it is from copper pipe, 
the copper was leached from a low pH of 7.0 or less. Make sure the pH is maintained over 7.0 to prevent further copper 
leaching from the pipes. You will only find copper piping near a heater or on very old houses. If the source is from a copper- 
based algaecide, you can try shocking the spa with a lot of liquid chlorine to "burn" it out, or simply start the ionizer up very low 
and do not allow the level to go over .40 ppm. Eventually the copper algaecide will dissipate.

 

SEQUESTERING AGENTS

 

Sometimes spa owners will add a flocking or sequestering agent to the water to remove stains or scaling in a spa or remove 
undesired minerals that are in the source water. 

Clearwater Enviro Tech 

sells a "Sequestering Agent" test kit that can test for 

stain, scale and mineral removers. Sometimes, some of these products can remove the copper-ions that you are about to 
introduce to the water.

 

For best results, you should test the Sequestering Agent Level before installing the Unit. 

Clearwater Enviro Tech 

dealers are 

recommended to get a test kit to test the Sequestering Agent Level in the water. Some products that will cause a problem 
include 

Sequasol

Cop-Out

Metal Magnet

Aluminum Sulfate 

or 

A

LUM

. Products that do not cause problems include 

Pool 

Stain Treat 

by 

United Chemical

, and 

Jack's Magic Products

. All polymer based products like 

Super Blue 

and 

Sea-Klear 

do 

not cause problems either.

 

If you do not have a test kit for Sequestering Agents, you should only worry about this if you are UNABLE TO GET THE 
REQUIRED COPPER-ION LEVEL in the water. You can send a water sample to 

Clearwater Enviro Tech 

for a free analysis. 

Please call the offices first. If the spa does have one of the products above that removes the copper-ions, simply shock the 
spa with a large amount of liquid chlorine to "burn" it out. Make sure the customer no longer uses this product. Without 
"burning" these Sequestering Agents out of the water, they may last several months in the water after the customer added it. 
Sometimes the customer forgets they added it in the first place.

 

Summary of Contents for MineralPURE SPA-1R

Page 1: ...с продажа и монтаж оборудования для бассейнов Тел 8 800 700 65 50 www bassein servis ru INSTALLATION SPA CARE MANUAL MODEL SPA 1R Outdoor Unit FOR ALLSPAS UP TO 2 000 GALLONS Phone 727 562 5186 www clearwater enviro com ...

Page 2: ...m CHLORINE OR BROMINE Always make sure there is some chlorine or bromine in the spa when first starting up the system as it may take several hours to fully ionize a spa Never add granular chlorine like HTH directly into the spa s water with the ionizer on It MUST be dissolved first or poured directly into the skimmer with the pump on Always make sure the water is clear before installing the ionize...

Page 3: ...ScaleBlaster to the system CYANURIC ACID Cyanuric acid is not required with the Clearwater Spa Purifier If the cyanuric acid level is over 150 ppm the spa should be partially drained and refilled with fresh water TOTAL DISSOLVED SOLIDS The Clearwater Spa Purifier requires some conductivity in the water for ionization to take place For the system to perform on maximum capabilities the TDS needs to ...

Page 4: ...If it is from copper pipe the copper was leached from a low pH of 7 0 or less Make sure the pH is maintained over 7 0 to prevent further copper leaching from the pipes You will only find copper piping near a heater or on very old houses If the source is from a copper based algaecide you can try shocking the spa with a lot of liquid chlorine to burn it out or simply start the ionizer up very low an...

Page 5: ... downward so that no air pocket can form in the electrode chamber If there is not enough give to allow insertion of the tee install unions 7 Screw the electrodes into the tee Generously wrap teflon tape around the electrodes several times before installing to prevent leaks INSTALLING THE SPA CONTROL BOX VOLTAGE SETTING 1 Before mounting the spa control box you must determine the voltage at the ins...

Page 6: ...his is all complete open up all valves and turn the power on Check for water leaks and all electrical connections for proper and firm connections SETTING THE CONTROL BOX Turn the control knob in a clockwise direction to turn the unit on To get the spa ionized as quickly as possible turn the control knob to Max so that you obtain the highest output With the proper pH readings the spa should be full...

Page 7: ...pa was just shocked with a lot of chlorine or bromine this can give you an improper test kit reading Always test the copper ion level before adding anything to the spa 9 Metal out removers As mentioned in the Sequestering Agent Level section in this booklet there are a few metal out removers or stain removers that can tie up the copper ion levels Test with a Sequestering Agent test kit or send wat...

Page 8: ... noted on the 5 Year Warranty Card If the unit is not covered under warranty the customer will be notified by phone or writing as to what the charge will be to repair REMOVING THE CIRCUIT BOARD If the control box needs to be replaced for any reason the unit was designed so that only the circuit board needs to be checked out This allows for all external electrical connections and the enclosure to r...