IF THE COPPER-ION LEVEL IS TOO LOW

 

Turn the control knob up (or clockwise) a notch. Test the following day. Continue this procedure till the Copper-Ion level 
stabilizes. Once you obtain the proper setting, this usually stays the same all season long. If the water gets colder, the chance 
of algae and bacteria decrease, thus a lower Copper-Ion level may be required. Be sure to test the Copper-Ion level weekly in 
case adjustments are needed.

 

FOLLOW DIRECTIONS AT THIS POINT FROM THE QUICK CHART (BLUE SHEET) INCLUDED 
WITH THE PURIFIER.

 

 

TROUBLE SHOOTING

 

CLOUDY WATER OR ALGAE

 

Brush the algae with a brush. Add chlorine or bromine to the spa. Check filtering system and backwash or clean two times a 
day till the water clears up. Check the water chemistry - especially pH and Total Alkalinity. Check the Copper-Ion level. The 
amount of chlorine or bromine needed depends on how cloudy the water is and how much algae there is in the spa.

 

 

CAN'T OBTAIN PROPER COPPER-ION LEVEL

 

1.) High algae growth and cloudy water may be using up all available copper-ions the unit can produce. Balance spa water 
and turn control knob up. See above.

 

2.) Correct sizing of spa. Is the spa more than 2,000 gallons? Is there a leak in the spa?

 

3.) Correct input voltage. Is the unit set to 115 VAC or 230 VAC - the same as the power source?

 

4.) Scaled, dirty or worn electrodes. Check electrodes for cleaning or replacing. Consult the owners manual for more details. 
5.) TDS level too low. See beginning chapter of this manual under "Total Dissolved Solids" on how to increase the water's 
TDS level.

 

6.) Improper test kit readings. Make sure you are following the proper Copper-Ion test kit procedures. Many people look at the 
side of the test tubes when testing instead of looking down from the top.

 

7.) Improper pH reading. The main problem of low or no copper-ion reading. Make sure the pH is under 8.0 and over 7.0 . 
When the pH is over 7.8, the copper ions fall out of solution.

 

8.) Too much chlorine or bromine in the spa. If the spa was just shocked with a lot of chlorine or bromine, this can give you an 
improper test kit reading. Always test the copper-ion level before adding anything to the spa.

 

9.) Metal out removers. As mentioned in the Sequestering Agent Level section in this booklet, there are a few metal out 
removers or stain removers that can "tie-up" the copper-ion levels. Test with a Sequestering Agent test kit, or send water 
sample to 

Clearwater Enviro Tech 

to confirm. If the spa does have a metal out remover that is affecting the system, simply 

shock the spa with a lot of chlorine or bleach to "burn it out".

 

10.) Steel plumbing. Never install the electrodes, pH probe or the Ion-Mate on steel piping. Cut out of section of this and 
replace with PVC pipe.

 

11.) Improper installation. Sometimes people install the electrodes on a return line, or bypass line that actually has no water 
flow going to it. Also check all wires for proper connections.

 

12.) Alternating lights do not come on the control box. See next section.

 

 

ALTERNATING LIGHTS DO NOT APPEAR ON THE CONTROL BOX

 

If for any reason you do not get a reading on the control box, and assuming all connections are correct, you should check the 
fuse.

 

A.) Remove control knob using very small screw driver by loosening screw on side of knob.

 

B.) Carefully lift each comer of the face plate (colored decal) and disconnect the four (4) screws 
C.) When all four (4) screws are removed, lift up the face plate and set aside.

 

D.) Disconnect the four (4) screws holding the printed circuit board in place.

 

E.) Lift printed circuit board up and turn over. Do not disconnect any wires. Very important. 
F.) Locate fuse on back of circuit board.

 

G.) Check fuse to see if blown.

 

H.) If blown, replace fuse with a replacement (Radio Shack Part # 270-1249). 
I.) Place printed circuit board in place again.

 

J.) Place collar in original location.

 

K.) Tighten in the four (4) screws to hold circuit board in place. 
L.) Screw face plate back on.

 

M.) Replace control knob in correct position and tighten screw to secure knob in place.

 

If the fuse was blown, try to determine what happened. If this repeats again, replace the fuse(s) again with a 250 mA, 5 X 20 
mm fast acting type (acceptable replacement Radio Shack stock number 270-1249). You may need to install a surge protector 
before the power source if this repeats again.

 

Summary of Contents for MineralPURE SPA-1R

Page 1: ...с продажа и монтаж оборудования для бассейнов Тел 8 800 700 65 50 www bassein servis ru INSTALLATION SPA CARE MANUAL MODEL SPA 1R Outdoor Unit FOR ALLSPAS UP TO 2 000 GALLONS Phone 727 562 5186 www clearwater enviro com ...

Page 2: ...m CHLORINE OR BROMINE Always make sure there is some chlorine or bromine in the spa when first starting up the system as it may take several hours to fully ionize a spa Never add granular chlorine like HTH directly into the spa s water with the ionizer on It MUST be dissolved first or poured directly into the skimmer with the pump on Always make sure the water is clear before installing the ionize...

Page 3: ...ScaleBlaster to the system CYANURIC ACID Cyanuric acid is not required with the Clearwater Spa Purifier If the cyanuric acid level is over 150 ppm the spa should be partially drained and refilled with fresh water TOTAL DISSOLVED SOLIDS The Clearwater Spa Purifier requires some conductivity in the water for ionization to take place For the system to perform on maximum capabilities the TDS needs to ...

Page 4: ...If it is from copper pipe the copper was leached from a low pH of 7 0 or less Make sure the pH is maintained over 7 0 to prevent further copper leaching from the pipes You will only find copper piping near a heater or on very old houses If the source is from a copper based algaecide you can try shocking the spa with a lot of liquid chlorine to burn it out or simply start the ionizer up very low an...

Page 5: ... downward so that no air pocket can form in the electrode chamber If there is not enough give to allow insertion of the tee install unions 7 Screw the electrodes into the tee Generously wrap teflon tape around the electrodes several times before installing to prevent leaks INSTALLING THE SPA CONTROL BOX VOLTAGE SETTING 1 Before mounting the spa control box you must determine the voltage at the ins...

Page 6: ...his is all complete open up all valves and turn the power on Check for water leaks and all electrical connections for proper and firm connections SETTING THE CONTROL BOX Turn the control knob in a clockwise direction to turn the unit on To get the spa ionized as quickly as possible turn the control knob to Max so that you obtain the highest output With the proper pH readings the spa should be full...

Page 7: ...pa was just shocked with a lot of chlorine or bromine this can give you an improper test kit reading Always test the copper ion level before adding anything to the spa 9 Metal out removers As mentioned in the Sequestering Agent Level section in this booklet there are a few metal out removers or stain removers that can tie up the copper ion levels Test with a Sequestering Agent test kit or send wat...

Page 8: ... noted on the 5 Year Warranty Card If the unit is not covered under warranty the customer will be notified by phone or writing as to what the charge will be to repair REMOVING THE CIRCUIT BOARD If the control box needs to be replaced for any reason the unit was designed so that only the circuit board needs to be checked out This allows for all external electrical connections and the enclosure to r...

Reviews: