11
When Connecting to Pump Motor
Ensure power to the pump is disconnected!
Disconnect the back plate to the motor where the electrical connections are. You will notice two connections
where the power source is connected to. Connect the
MineralPURE SPA-1R
black, white and green wires
to the same as the motor. If connected properly, the unit should come on and off with the motor.
When Connecting to a Regular Outlet or Electrical Junction Box
It is possible to connect the control box to a regular outlet or junction box.
Although this is not recommended
because the control box should shut off whenever the spa/hot tub’s pump motor is off. If the SPA-1R
control box is left running when there is no water flowing past the electrodes, damage to the electrode
or electrode cell chamber could result.
The control box has a ½” flexible conduit connector on it, so provisions will have to be made for the outlet or
the junction box to be similarly equipped. The wiring color codes scheme is the same as the North
American Standard.
- Black is line
- White is neutral
- Green is ground