19
Can't Obtain the Proper Copper-Ion Level (Continued)
13.) To Determine Actual Output of the SPA-1R
There is a way to determine the actual milliamp charge going to the electrodes while the electrodes are in the water and
the
SPA-1R
turned on.
By using a standard multimeter to read out DC current (an LCD Digital is preferred), take one of the connectors either the
red (positive) or the black (negative) and connect it to one of the electrode terminals. Take the other connector and
hook it up with one of the electrode wires (black or red) coming from the control box. The other wire from the control
box should remain hooked up to the electrode terminal. This hookup, while running in series, will give you the actual
milliamp output of the ionizer at the given moment. The
SPA-1R
should read about
mA on max (setting
).
40
MAX
NOTE: These actual readouts will vary slightly, so do not be alarmed if you get a reading over 40 mA on the
SPA-1R
. The
readings should lower as the control knob is turned to a lower setting.
If the TDS level is not at least 500 ppm, the readings will be lower.
The electrode chamber must be full of water with the filtering system on for this to give you an accurate readout.
14.)
Indicator lights do not come on.
Make sure the
SPA-1R
has been installed properly to the correct voltage. Make
sure power is going to the main source. Check fuse inside the
SPA-1R
control box.
To check the fuse, first open up the
SPA-1R
control box:
TURN OFF ALL POWER FIRST!!!!
1.) Open up the clear lid. *(see page 8 on photos of how to open and close up control box)
2.) Unscrew the four (4) screws holding the faceplate assembly in place.
3.) Lift up faceplate assembly and flip over.
4.) Locate fuse and check. (see page 20 for photo)
5.) Replace fuse if blown (5mm x 20mm 20V, 1/4A, fast acting)
6.) Mount faceplate assembly back in place
7.) Tighten four (4) screws to secure.
If the fuse was blown, try to determine what happened. If this repeats again, you may need to install a surge protector
before the power source.
If the fuse was not blown, and you get no output at all, check the back of the circuit board for anything unusual - loose
parts, burn marks, etc. If this is the case, call your
dealer
or
Clearwater Enviro Tech
direct to return the circuit
board.
YOU MUST OBTAIN AN "RMA" NUMBER BEFORE RETURNING ANY EQUIPMENT FOR
REPAIR.
This
SPA-1R
was designed for easy removal of the circuit board. See next section for directions to remove circuit board.
THERE IS NO NEED TO RETURN THE ENTIRE CONTROL BOX. THIS WILL SAVE TIME AND
SHIPPING COSTS AT BOTH ENDS.
J.) Troubleshooting (continued)
Multimeter
Control Box
on and plugged in
Electrode connected
and full of water