Mounting the Control Box
1.)
Before mounting the
SPA-1R
control box, you must determine the voltage at the installation site. By using
your voltage meter, determine if the voltage is 115VAC or 230VAC.
ALL SPA-1R CONTROL BOXES ARE FACTORY SET AT 230 VAC.
IF THE INSTALLATION CALLS FOR A 115 VAC SETTING,
YOU WILL NEED TO MAKE AN ADJUSTMENT TO THE SPA-1R CONTROL BOX.
Changing Voltage from 230VAC to 115VAC
a.) Open up the clear control box panel.
b.) Unscrew the four (4) screws holding the faceplate assembly in place.
c.) Lift the face plate out of the enclosure and turn over. Do not disconnect any wires!
d.) Locate switch on circuit board (between fuse and transformer) where 230V - 115V wording is
located. (see page 20)
e.) Slide switch from 230VAC to 115VAC.
f.) Place the faceplate assembly back in its place.
g.) Retighten four (4) screws to hold in place.
FAILURE TO SET THE SPA-1R ON THE PROPER VOLTAGE CAN CAUSE PROBLEMS:
If the actual voltage was 230VAC, and the
SPA-1R
was set on 115VAC, the internal fuse will blow.
If the actual voltage was 115VAC, and the
SPA-1R
was set on 230VAC, the
SPA-1R
will not work
at 100% efficiency.