14
Indicator lights:
What they mean
Chlorine Output.
A series of six lights indicate the chlorine output setting of the power pack. More lights equals
greater chlorine production.
Note:
This setting does not show the actual chlorine reading in
the pool. Use of a test kit is required to confirm the Salt Level or Free Chlorine reading of the
pool water.
Chlorine Output - Yellow Light Flashing.
The yellow (low output) light flashes for a few minutes during cell reversal (cell self clean)
indicating no output during this time.
Super Chlorinate - Light ON.
This light indicates that the Super Chlorinate feature has been selected, it will turn OFF when
the Super Chlorinate period has ended.
Super Chlorinate - Light OFF.
Function not selected.
Add Salt - Light ON.
The Add Salt light will come on at any salt level between 3000ppm and 4000ppm depending on
mains voltage and water temperature (below 65˚).This is not a fault but a precaution to ensure
the salt level is never too low. (See ‘Salt:When And How To Add It’). Note: Operating the LM-2
at reduced salt levels may shorten the life of the cell.
Add Salt - Light OFF.
Indicates that the salt level in the pool is correct.
No Flow - Light ON.
This indicates insufficient water flow in cell, usually caused by the pump not running. The
chlorine output will also turn off at this time.
All Lights OFF.
All lights OFF indicates the LM2 is turned off.Turn unit ON. If lights are still OFF, check the
resettable fuse and circuit breaker.
INDICATOR LIGHTS – WHAT THEY MEAN