Condensing Economizers
2-2
Part No. 750-266
2.1-GENERAL
The C-B condensing economizers are essentially static reactive type heat exchangers. The performance
of this type of exchanger is ultimately dependent upon the dynamic conditions of temperature,
pressure and mass or flow available on both the liquid and gas side.
The units are virtually maintenance free, having no moving parts except the internal gas bypass
assembly.
Each economizer includes the C-B exclusive internal stainless steel by-pass damper to divert the waste
heat through the fin tubing or bypass a portion up through the center or modulate according to
performance requirements.
Figure 2.1 - Gas flow, operating (damper closed) and bypass
The C2X condensing economizer consists of two sections - the upper section for preheating incoming
boiler feedwater before it goes to the deaerator, and a lower section for further heating of the feedwater
after it leaves the deaerator.
The C1X (or the C2X upper stage) can also be used to heat any other liquid besides boiler feedwater.
By matching the economizer with the appropriate motor and combustion air fan, fuel-to-steam
efficiencies of over 90% can be reached.
2.2-UNLOADING
Prior to manufacture all exchangers were represented with the issuance of an AutoCAD drawing to
scale for customer approval. This drawing can be used to prepare for installation and provide for
special equipment movement needs.
Cleaver Brooks inspects all equipment prior to shipment and cannot be held responsible for damage
caused in transit. In addition, all electrical devices are also thoroughly tested to assure that they
operate according to design specifications.
All exchangers are shipped via common carrier. Take care to inspect the heat exchanger when you
receive it and make any claims for damages immediately to the carrier within the allowable time limit.
Exhaust gas flow - normal operation (door view)
Exhaust gas flow - bypass operation (left side view)
Summary of Contents for C1X Series
Page 1: ...Economizers 750 266 1 15 CRE CCE C2X C1X Operation Manual...
Page 2: ......
Page 6: ...vi NOTES...
Page 20: ...Standard Economizers 1 14 Part No 750 266 Figure 1 7 Piping with circulating tank BOILER...
Page 29: ...Condensing Economizers Part No 750 266 2 9 Figure 2 7 Dimension diagram C2X BB...
Page 33: ...Condensing Economizers Part No 750 266 2 13 Figure 2 9 Single boiler with deaerator...
Page 39: ...Condensing Economizers Part No 750 266 2 19 Figure 2 11 Two boilers with deaerator...
Page 51: ...Condensing Economizers Part No 750 266 2 31...
Page 52: ...e mail info cleaverbrooks com Web Address http www cleaverbrooks com...