7
TRANSDUCER SPECIFICATIONS
MAXIMUM TORQUE CAPACITY
See full scale values below
OUTPUT VOLTAGE (Vo)
2 Millivolts per volt at maximum torque capacity
BRIDGE RESISTANCE (Rbr)
700 ohm (nominal) can be used with 350 and 700 ohm strain gage equipment*
TRANSDUCER CABLE
Cannon No. PTO1A0P (mates with Cannon No. PTO1A0S or equivalent)
CALIBRATION INSTRUCTIONS
ANGLE HEAD SIZE FULL SCALE VALUE (FS)
FT. LBS. Nm
M
95.7
129.8
P
99.3
134.6
T
118.5
160.7
In order to calculate the calibration value for the system in % full scale, the following formula may be used:
% FS = Rbr
1
1
------------------ X ----- X -----
2(Rcal) + Rbr Vo
2
Where Rcal = Calibration Resistor Value in ohms of the torque monitor used.
The following is an example of a 55 series right angle tool, a "P" head and a torque monitor with a 110,000 ohm calibration
resistor.
The values are: FS = 99.3 ft. lbs.
Rbr = 700ohm
Vo = .002
Rcal = 110,000ohm
700ohm 1
1
% FS = --------------------------- X ------ X ----- = 79.3%
2(110,000ohm) + 700ohm .002
2
Calibration Value = 99.3 (.793) = 78.7 ft. lbs.
*Calculated calibration value should be doubled if a torque monitor designed for use with a 350ohm bridge resistance
transducer is used.
A
A
B
B
C
C
D
D
BLACK
GREEN
RED
WHITE
TOOL RECEPTACLE
CABLE CONNECTORS
R
WIRING DIAGRAM
E
E
F
F
(+) SIGNAL
(-) SIGNAL
SHIELD
(+) EXCITATION
(-) EXCITATION
Ro/2
Rm/2
R
R
R
t
C
t
C
Ro/2
Rm/2
Rcal
R= Gage Resistance
Rm= Modulus Resistor
Ro= Output Scaling Resistor
Rm & Ro may be omitted
Rcal= Shunt Calibration Resistor
Summary of Contents for 55NLTVC Series
Page 21: ...21...
Page 22: ...22 NOTES...
Page 23: ...23 NOTES...
Page 24: ...24 670 Industrial Drive Lexington SC 29072 Phone 803 359 1200 Fax 803 359 2013...