17
1
EN
Tool
WLAN
Torque
Nm
(ft-lb)
Speed
r/min
Weight
A
B
C
Output
Order no.
Min.
Max.
Min. Max.
kg
(lb)
mm
(in)
mm
(in)
mm
(in)
CLBP04Q
CLBPW04Q-(...)
1.1
(0.8)
4.0
(2.9)
177
1770
1.05
(2.3)
213.5
(8.41)
209.0
(8.23)
28.5
(1.12)
1/4"
CLBP08Q
CLBPW08Q-(...)
2.1
(1.5)
8.0
(5.9)
99
985
1.05
(2.3)
213.5
(8.41)
209.0
(8.23)
28.5
(1.12)
1/4"
CLBP12Q
CLBPW12Q-(...)
3.2
(2.4)
12.0
(8.8)
70
700
1.05
(2.3)
213.5
(8.41)
209.0
(8.23)
28.5
(1.12)
1/4"
Values without battery
9 Ambient conditions
Features
Data
Operation site
Indoors
Working temperature
0 °C – 40 °C
Storage temperature
-25 °C – 65 °C
Type of cooling
Convection (self-cooling)
Relative humidity
10 % – 90 %, no condensation
Working height
Up to 3000 m (9,843 ft) above sea level
Degree of protection as per DIN EN60529 (IEC60 529)
IP40
10 Troubleshooting
10.1 Tool
Problem
Possible causes
Measure
Tool does not start
No speed (RPM) programmed.
►
Program speed for all active stages.
Tool temperature is too high.
►
Cool down the tool.
Battery voltage is too low.
►
Change battery.
Tool not recognized.
Software is incorrect.
►
Check
CellClutch
laptop/PC software.
Connection to laptop/PC is not
available.
►
Check USB cable.
►
Check PC driver.
Tool is defective.
►
Change tool.
Tool starts in tightening direc-
tion, but not in counterclock-
wise rotation.
No speed programmed for
counterclockwise rotation.
►
Program the counterclockwise rotation: In the
CellClutch
PC software, set the
Rotation
to
Reverse
in the
Forward and Reverse Application
Settings
and parameterize the
Speed
.
If
Forward
is selected for
Enabled Direction
, the
counterclockwise rotation of the
reverse switch has no function.
Tool does not start with coun-
terclockwise rotation activated.
With counterclockwise rotation,
parameter for Speed is 0 rpm.
►
Program the speed for counterclockwise rotation:
In the
CellClutch
PC software, set the
Speed
and
Rotation
in the
Forward and Reverse Appli-
cation Settings
.
Summary of Contents for CellClutch CLBA