Menus and Functions
20
P2398PM |
2019-12
Apex Tool Group
3
EN
For a torque shutoff, enter the shut-off torque.
For an angle shutoff, enter the shut-off angle.
Once the value has been reached, the tightening process is completed. This setting
option is the same as in the menu 3.6.4 Advanced settings, page 22.
Note
If the shut-off value is entered here in the
Configuring FastApps
menu, then the follow-
ing values are calculated automatically:
Parameter
Torque shutoff
Angle shutoff
Low torque
-15% of the shut-off torque
Threshold torque
MaxTorque
+15% of the shut-off torque
Tool capacity
Minimum angle
0
-15% of the shut-off angle
Maximum angle
9999
+15% of the shut-off angle
Threshold torque
1/4 x shut-off torque
Manual input
Final speed
50
50
Speed threshold
1/4 x shut-off torque
Threshold torque
These values can be changed manually in the
tings, page 22.
Entering the threshold torque.
This button is only displayed during angle shutoff. This setting option is the same as in
the menu 3.6.4 Advanced settings, page 22.
Batch display
Enter the number of tightening positions for a FastApp.
Start speed display.
Enter the start speed.
Advanced settings.
Cross-Thread Detection activated.
If cross-thread detection is enabled, a block angle of 180° is added to torque/angle
shutoff. This block angle is used at the start of rundown, to detect if screw is already
tighten or thread/screw damaged or crooked screwed-in. The angle counting starts
after the block angle.
So if within that first 180° the torque exceeds the shutoff-torque (torque shutoff) or
maximum torque (angle shutoff), the rundown is aborted and the "BLOC" error is show.
Cross-Thread Detection disabled.
Reset FastApps.
Button
Description
ADV
ADV
Bl
Bl
Summary of Contents for CellCore CCBA