Apex Tool Group
P2398PM |
2019-12
49
Menus and Functions
3
EN
svg file
In the .
svg
file, the data points of the .csv file are displayed graphically.
The name of the
.svg
file contains the date and time when the result was recorded. The ID in the file name
corresponds to the
GraphicID
column from the table of the archive, see 3.11.2 Saving an archive, page 45.
In this way, each graphic can be assigned to a measurement result from the archive:
graphic_ID_year_month_day_hour_minute_second.svg
.
The scaling of the axes depends on the measured values. The graphic recording ends when the switch-off
values have been reached.
Fig. 3-44: Graphics export – Torque graph
The .
svg
file contains the following values:
Angle high
[deg]
Maximum Angle
Angle [deg]
Shut-Off Angle
Target
Switch-Off value, depending on the selected tightening strategy the unit is [Nm] or
[deg].
Shutoff reason
Shut-Off reason
Angle [deg]
Angle
Time [ms]
Time
Torque 1 [Nm]
Torque
Torque 2 [Nm]
Torque (redundancy)
Current [A]
Current
Speed [RPM]
Speed
Designation
Description
Tool Type
Tool type with which the tightening was done
Tool Serial
Serial number of the tool
Date
Date of export: Day.Month.Year
Time
Time of export: Hour:Minute:Second
App
Number of the FastApp
ID
Number of the graphic entry. The number is identical to the
GraphicID
for the archive.
Tq low [Nm]
Minimum Torque
Tq high [Nm]
Maximum Torque
Tq [Nm]
Shut-Off Torque
Ang low [deg]
Minimum Angle
Ang high [deg]
Maximum Angle
Designation
Description
Summary of Contents for CellCore CCBA