Tightening sequence
56
P2398PM |
2019-12
Apex Tool Group
4
EN
4
Tightening sequence
In the FastApps mode, there is a choice between two tightening sequences:
•
Torque shutoff: Sequence 31 torque controlled, extended monitoring
Shut-off torque-controlled tightening sequence with torque and angle check.
Abb. 4-1: Representation of torque shutoff
•
Angle shutoff: Sequence 51 angle-controlled, extended monitoring
Shut-off angle-controlled tightening sequence with angle and torque check.
Abb. 4-2: Representation of angle shutoff
The following description applies to both tightening sequences.
For the speed, select a second speed parameter
Final Speed
. The behavior at the
Final Speed
is different
in FastApps and mPro mode:
•
FastApps mode: If this is parameterized, the speed immediately changes from the start speed to the
final speed up to the maximum torque.
•
mPro mode: If this is parameterized, the speed is reduced from the starting speed to the final speed
starting from the threshold torque to the maximum torque.
The final speed must be lower than the standard speed.
The angle counting starts when the
Threshold Torque
is reached.
After switching off via the
Shut-Off Torque
/
Shut-Off Angle
, the torque that develops or the associated angle
is compared with the
Minimum/Maximum Torque
and the
Minimum/Maximum Angle
and evaluated OK/
NOK accordingly.
Angle
Torque
Shut-Off Torque
Minimum Torque
Maximum Torque
Threshold Torque
Start
Maximum Angle
Minimum Angle
Angle
Torque
Shut-Off Angle
Minimum Torque
Maximum Torque
Threshold Torque
Start
Maximum Angle
Minimum Angle