32
P1891E/EN 2014-02
1891c-enu_LCD_bedingt.fm, 25.04.2014
LCD display
7
7.3.5
Diagnostics submenu
Emergency mode off.
If the emergency mode has been enabled on the control, see
See
Advanced Application Builder\System Settings\Enable
Emergency Mode
The emergency mode can be enabled and disabled via the tool start button or by pressing
<F2> for 2 seconds. The emergency mode is disabled automatically when the tool links to
the control.
Emergency mode on.
If the emergency mode is enabled and
Linking
is disabled, the fastening parameters of
the last selected Application are used. For
Linking
operating mode, all steps are used with
the corresponding parameters of the last selected Tightening Group.
The memory of the tool stores data from up to 512 rundowns. If more rundowns than this
are executed while emergency mode is active, the oldest results are always discarded
once 512 rundowns have been recorded.
Emergency mode
active. Is displayed during fastening.
Only for models of the 47BAYP(…) series
Activating add-on parts fitted on platform (scanner, TAG…).
TQ calibration
This test function cyclically recalibrates the system with the values used immediately
before the start of a rundown. For this, the tool must not be tensioned!
First line: Calibration test and status.
Second line: TQ calibration voltage.
Third line: Offset voltage. If a value lies outside the tolerance range, the corresponding
error is displayed.
TQ measurement
In this test function, after the start button is pressed, the same calibration is carried out as
immediately before the start of a rundown. For this, the tool must not be tensioned!
Then, the tool starts with speed "0". The torque is continuously measured and displayed
until the start button is released.
Second line: Current torque.
Third line: Peak value, highest value since the start button was pressed.
Emerge
Strate
Off
Emerge
Strate
On
Emerge
Mode
Active
Platf
None
Cal OK
K 1.11
O 0.00
Value
Rated value Tolerance
TQ calibration voltage:
1.10 V
± 45 mV
Calibration offset
0 V
± 58 mV
Torque
T 5.57
T 8.23