1891g-enu_TechnDaten_bedingt.fm, 25.04.2014
P1891E/EN 2014-02
85
Service
12
Series 47BAY(…)
11.7.8
Torque transducer
Torque is measured by a reaction transducer with expandable measurement strips. The reaction transducer
is positioned between the motor and the gears in the handle housing.
12
Service
Features
Data
Standard
IEEE 802.11a/b/g/n
Safety
•
WEP 64/128-bit encryption
•
WPA-TKIP/WPA2-AES(CCMP)
•
802.1x EAP authentication
LEAP, PEAP
1)
, EAP-TTLS
1) PEAP (without client certificate)
Range
Typically up to 50 m (164’ 0.5”)
Channels
•
1 - 13 (2.412 - 2.472 GHz)
•
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 132, 136, 140, 149, 153, 157,
161, 165 (5.180 – 5.825 GHz)
Transmission
power:
20 dBm typ. @ 2.4 GHz
15 dBm typ. @ 5.0 GHz
Sensitivity
-94 dBm (typ. @ 1 Mbps, 2.4 GHz)
-80 dBm (typ. @ 5 GHz)
Modulation
DSSS / OFDM
Standards
EN 300 328-1 V1.7.1
EN 301489-1, -17
EN 301893 V1.5.1
EN 60950
FCC Part 15
IC (Industry Canada)
Features
Data
Nominal calibration
see , page 78
Sensitivity
2mV/V
Bridge ohms
1000 Ohm
Precision class
0.5% of final value
Linearity error
+0.25% of final value
Measurement range
-125% to +125% of final value
If repair is required send the complete 47BA to
Sales & Service Centers
. Repairs on the gears and angle
attachment are only permitted by Apex Tool Group authorized personnel. If the tool is opened, the warranty