background image

       IMPORTANT SAFETY INSTRUCTIONS
  READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE

DO NOT OPERATE THE MACHINE WITHOUT READING AND UNDERSTANDING THE 
OPERATING INSTRUCTIONS. IF THE MACHINE IS OPERATED INCORRECTLY IT CAN POSE 
DANGER TO THE OPERATOR AND OTHERS AND WILL INVALIDATE THE MANUFACTURERS 
WARRANTY. BEFORE USE, READ AND UNDERSTAND THE FOLLOWING:

1. A Risk Assessment for the works to be undertaken.
2. MSDS Chemical Data Sheet.
3. Risk Assessment for Chemical use.

IMPORTANT NOTICE:

Before inserting the batteries and gum removal solution correctly 

t the machine

to the operator by adjusting the straps 

as required

. The machine’s body has been designed to 

be kept upright at all times when the batteries are inserted to drawer and gum removal
solution is in the water tank. This is important to the operation of the machine.

Cautions when using the machine:             

    Keep the body upright at all times when operation or when chemical or 
    batteries inserted.

    The rechargeable battery has been designed to be fully charged BEFORE 
    each use

Only use the approved solution and batteries for the safe use of the machine.
Using other consumable items in the machine invalidated the warranty and 
will lead to damage of the internal parts of the machine and also may pose 
a risk to the operative.

Make sure the operator has read and understood these instructions before 
attempting to use the machine and is fully trained in its operation.

Consumable Items:

Chemical (2 Litres) will last for approximately 2 hours of continual use. 4x chemical
bottles will last for approximately 8 continual hour’s operation.

The brushes will wear according to the surface being cleaned. Each Brush will last
for approximately 4 hours. 2x Brushes will last for 8 hours continual operation. 
Only use the speci

cally designed brush as this has a jet incorporated for machine

to work correctly.

Choose a steel wire brush for solid urban surface such as concrete, natural stone, 
tarmacadam, asphalt and other common urban surfaces. Choose a nylon brush
for soft surfaces such as manmade 

ooring, sandstone, heavy-duty carpet. 

02

Summary of Contents for I-GUM

Page 1: ...BATTERY POWERED OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web www clemas c...

Page 2: ...tallation 2 Using the machine Turning OFF the machine Maintenance Trouble shooting Machine Parts Accessory Electrical Diagram Exploded drawing and spare parts list Product Speci cation Instruction for...

Page 3: ...ALL INSTRUCTIONS BEFORE USING THE MACHINE R LITHIUM ION BATTERY Nominal Voltage 24V Energy Capacity 353 Wh SAFETY ADVICE Do not crush pierce or damage in any way Do not heat or incinerate Do not shor...

Page 4: ...erted The rechargeable battery has been designed to be fully charged BEFORE each use Only use the approved solution and batteries for the safe use of the machine Using other consumable items in the ma...

Page 5: ...ck Each service pack provides a continuous 8 hours operation and consists of 4x Chemical Bottles 1x Nylon wire Brush 3x Steel wire Brush 03 Warranty The Chewing Gum Removal machine should only be oper...

Page 6: ...sh 1x Water Drop Disk 1x Brush Storage Tube 1x Accessory Battery Charger 1x Power Cable Steel Wire Brush 3x Top Battery 1x Bottom Battery 1x MAIN BODY 1x LANCE 1x Machine When you open the color box a...

Page 7: ...rts Lance Control panel Trolley handle Broom Shoulder harness Waistband Water drop disk Wheels Hose Fluid inlet hole Brushes Storage Tube Battery Power Display Battery Drawer Drawer Handle Power Switc...

Page 8: ...re or nylon wire brush onto the end of the nozzle of the lance close open 3 Place the lance in the lance holder of body There are 2 magnets which hold the lance in position The lance needs to be remov...

Page 9: ...OM 4 Open the brush storage tube cap and you can place the brushes in the tube Insert the brush storage tube to the holder of body 6 Insert the broom to broom holder of body The Broom needs to be remo...

Page 10: ...atteries Installation 2 Before operating the machine 1 Ensure that the battery has been fully charged before each operation Before you charge the battery please read the INSTRUCTION MANUAL OF BATTERY...

Page 11: ...ator 00000000 Timer for machine using hours Main Switch For Power Supply INSTRUCTION FOR BODY CONTROL PANEL INSTRUCTION FOR WATER LEVEL INDICATOR The uid tank capacity is 2 5L Each use we can input on...

Page 12: ...heating indicator will be bright After few seconds the steam temperature will be raised After about 20 seconds uid will be heated to steam and the steam will come out from brush of lance Change the L...

Page 13: ...pressure The weight of the lance with agitation is all that is required Remove the lance from the gum and use a broom to sweep across the area to ensure the gum has been destroyed or if further clean...

Page 14: ...by the manufacturer 4 Make sure the batteries are charged 100 on the rst charge Machine maintenance The BATTERY VERSION I GUM machine requires very little maintenance Wipe down the machine periodicall...

Page 15: ...battery The pump does not run Replace pump The steam outlet hole is blocked Change to use a new brush Water level indicator LED light is ushing The chemical is low in the tank Pour the chemical into...

Page 16: ...g Broom Extended Length 1 3 M Li ion Battery DC24V 25 2V 14Ah 353Wh Tank Capacity 2 5 L Operation Time of Battery About 50 min 1 Battery Battery Drawer Can install 2x Batteries Fluid Flow Speed Class...

Page 17: ...79 9 Cable wire for battery supply 106 2189 0 wire for water detecting connector 106 2079 5 wire for tank LED light 106 2079 8 LED light PCB for Fluid Tank 106 2185 0 7 Poles Circle female connector S...

Page 18: ...I GUM LANCE EXPLODED DRAWING Exploded drawing and spare part list 16 page 1 8...

Page 19: ...e PA66 20 GF 1 20 69 0022 1 Screw M3 10 SUS 304 1 21 72 0206 1 Screw Counter sunk bolt M4 8_SS SUS 304 3 22 106 0205 0 Steel tube for outlet connector SUS 304 1 23 106 1111 9 M4 8 Flat head machining...

Page 20: ...BODY UNIT EXPLODED DRAWING1 18 page 3 8...

Page 21: ...BODY UNIT EXPLODED DRAWING2 19 page 4 8...

Page 22: ...oard 1 21 106 2071 0 Timer 1 22 106 2101 0 Sticker for battery power PC 1 23 106 2194 0 MAIN SWITCH 4 P 16A 250V 1 24 S 106 2006 0 Bottom Housing parts assm see exploded drawing ABS UL94 V0 1 25 S 106...

Page 23: ...ut M4 nylon stainless steel SUS 304 5 51 106 1111 23 M4 16 PAN HEAD SELF TAPPING SCREW SUS 304 2 52 106 2106 0 Fitting bracket for pump ABS UL94 V0 1 53 106 2006 0 Bottom Housing ABS UL94 V0 1 54 106...

Page 24: ...support rod for battery drawer AL 6 72 0206 1 Screw counter suk bolt M4 8 SS SUS 304 4 7 72 0068 357 Battery connector male Gray POM 8 106 2004 0 Handle of drawer ABS 9 106 1111 22 M3 8 Flact head mac...

Page 25: ...nnector PVC Cu 1 7 106 2104 0 Hard tube for uid pump outlet PC Silicon Rubber 1 8 106 2187 1 Wires xator Nylon 4 9 106 2178 0 Silicon Rubber Ring 13 8 3mm Silicon rubber 1 10 106 2176 0 Tank water out...

Page 26: ...rink and animal feedingstu s S46 If swallowed seek medical advice immediately and show this container or label SECTION 3 Composition information on ingredients 3 2 Mixtures 67 548 EEC 1999 45 EC Chemi...

Page 27: ...afe storage including any incompatibilities Keep in a cool dry well ventilated area Keep containers tightly closed SECTION 8 Exposure controls personal protection 8 2 Exposure controls 8 2 1 Appropria...

Page 28: ...tion 15 1 Safety health and environmental regulations legislation speci c for the substance or mixture REGULATION EC No 1907 2006 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006 conc...

Reviews: