OPERATION
24
T12 9009918 (3--2013)
DOUBLE SCRUBBING
Use the double scrubbing method to clean heavily
soiled areas.
Double scrubbing can be performed using the
ec--H2O
SCRUBBING SYSTEM (option) or
CONVENTIONAL SCRUBBING methods.
To raise the side squeegees for double scrubbing,
remove the clevis pins from the storage locations.
Manually raise both side squeegee assemblies,
then reinsert the pins into the holes in the side
squeegee brackets.
Press the
1--STEP button
and then the V
acuum
fan/squeegee button.
The light above the
Vacuum
fan/squeegee button
will turn off, the squeegee
will rise, and the vacuum fan will stop operating.
Scrub the heavily soiled area. Let the cleaning
solution soak on the floor for 5--15 minutes.
T12
T12XP
FOR SAFETY: When using machine, go slowly
on inclines and slippery surfaces.
Before scrubbing the floor a second time, lower
the side squeegees and press the
V
a
cuum
fan/squeegee button
to lower the rear squeegee
and turn on the vacuum fan. The light above the
button will come on. Scrub the floor a second time
to pick up the cleaning solution.
WARNING: Flammable materials or
reactive metals can cause an explosion
or fire. Do not pick up.
NOTE: To turn off the solution flow when
scrubbing the area a second time, press the
Solution on / off button Press the Solution on / off
button again to restart the solution flow.
T12
T12XP
NOTE: Double scrubbing is not recommended in
areas where the cleaning solution will run under
racks or damage products.