14. Inspect the condition of the scrub head skirt,
replace if worn or damaged (Figure 69).
Cylindrical Brush Model
FIG. 69
15. FaST Model: Connect the FaST--PAK supply hose
to the storage plug when not in use (Figure 70).
Remove any dried concentrate from the hose
connector by soaking it in warm water.
FIG. 70
16. Clean wet/lead acid batteries to prevent corrosion
and check for loose battery cable connections (See
BATTERY MAINTENANCE).
17. Recharge the batteries (Figure 71). To prolong the
life of the batteries, only recharge the batteries if
the machine was used for a total of 30 minutes or
more.
FIG. 71
MONTHLY MAINTENANCE
1. Check the cylindrical brush belt tension every 100
hours (Figure 72). Belt tension should flex 3mm at
midpoint, with 1.13--1.22 Kg force.
WARNING: Electrical Hazard. Disconnect
Battery Cables Before Servicing Machine.
Cylindrical Brush Model
FIG. 72
2. Inspect and clean the recovery tank cover seal
(Figure 73). Replace if damaged.
FIG. 73
3. Lubricate all pivot points and rollers with a water
resistant grease.
4. Lubricate the casters with a water resistant grease
(Figure 74).