PULSAR
®
PLUS 55-S SUCTION BLAST CABINET
Page 18
© 2021 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 30423
Figure 20
5.8.3
As the filter cartridge cakes with dust, differential
pressure increases, and the pulse-pressure setting may
not adequately clean the cartridge (does not reduce
differential pressure below 4" WC, as noted on the
differential-pressure gauge). When differential pressure
reaches 4” WC, increase pulse pressure by increments
of 10 psi, up to the maximum of 100 psi.
5.8.4
When the maximum pulse pressure of 100 psi is
reached and pulsing does not lower differential pressure
below the changeover pressure of 4" WC, decrease
pulse OFF time to 20 seconds, per Section 5.9.2.
5.8.5
When differential pressure stays above 4" WC.
after increasing pulse pressure to 100 psi and
decreasing OFF time to 20 seconds, replace the
cartridge, per Section 7.12.
5.9
Digital Pulse-Control Timer
The pulse timer is attached to the diaphragm pulse valve
located on the dust collector pulse reservoir as shown in
Figure 21.
Figure 21
5.9.1 Operating principles Figure 22
NOTE: There is no need to set the timer functions or
subranges.
If the timer function is accidentally changed, refer to
Section 5.9.4 to reset it to Function "A".
If timer subranges are accidentally changed, refer to
Section 5.9.5 to reset them to factory settings.
5.9.1.1
The LED display comes on when the green start
pushbutton is pressed and power is supplied to the timer
TE S T
of
f
on
on
TE S T
of
f
on
on
FACTORY SETTINGS
Figure 22
5.9.1.2
The timer is factory set at 40 seconds OFF and
150 milliseconds (0.15 second) ON, as shown in Figure 22.
Every 40 seconds, the cartridge is pulsed for 0.15 second.
5.9.2
Setting pulse OFF time (time between each
pulse) ‒ Figure 23
NOTE: The numbers shown in Figure 23 signify the
following step numbers:
1. Make sure the OFF subrange is set to seconds. The
sec (seconds) indicator light should be lit, as shown in
Figure 23. If the subrange is other than seconds,
reset it as noted in Section 5.9.5.1.
Pulse Timer
Pulse Valve
Pulse Reservoir
UNLOCKED
LOCKED
Push insert to center
to unlock.
Push insert to either
side to lock.
40
OFF TIME
The sec (seconds)
indicator light is lit
(indicating the
subrange is set for
seconds), and time is
set for 40 seconds.
15
The min (minute) and sec
(seconds) indicator lights
are both lit (indicating the
subrange is set for
milliseconds) 10 times
the value shown on the
display, or 0.15 seconds
(150 milliseconds).
ON TIME