72
English
Trouble shooting
When working on the electrical
system of the whirlpool, power must
be turned off by the main switch
or fuse.
Type of Malfunction/Cause
Possible Cause
Possible Clearance
• Air system does not function
• Is voltage applied?
- Are fuses inserted?
- Malfunction in electrical mains
- Are the plug connections to the control correctly seated?
• Control does not react
• Control defective
• Control element defective
• Blower defective
•
- Insert fuse
- Call electrician
- Pull and reinsert plug
• Reconfi gure Poolmaster
• Replace control
• Replace control element
• Replace blower
• Hydro system does not
function
• Nozzle dirty
• Is voltage applied?
- Are fuses inserted?
- Malfunction in electrical mains
- Are the plug connections to the control correctly
seated?
• Is the water level high enough?
• Water level sensor does not react
• Control does not react
• Control defective
• Control element defective
• Hydraulic pump defective
• Clean nozzle
•
- Insert fuse
- Call electrician
- Pull and reinsert plug
• Continue to fi ll tub
• Adjust sensor
• Replace sensor
• Reconfi gure Poolmaster
• Replace control
• Replace control
• Replace control element
• Replace hydraulic pump
• System switches itself on wit-
hout an obvious reason
• Automatic cleaning function of the air nozzles
• Has the room temperature changed (e.g. fl oor heating
underneath the whirlpool)
• Has the humidity in the room changed (e.g. use of a
shower in the same room)
• Were cables, water pipes or other electrically con-
ductive materials laid in the area of the water level
sensor?
• Is/was cleaning work performed near the tub? (e.g. mo-
ist cleaning cloth near the water level sensors)
• Okay
• Readjust sensitivity of the water level
sensor
• Readjust sensitivity of the water level
sensor
• Reposition cables, water pipes or similar
• Remove objects from the tub
• Water nozzle
• Nozzle dirty
• Nozzle head not adjustable
- is seized
- is loose
• Clean nozzle
- Reposition O-ring behind head
- Replace O-ring behind head
• Leakage
- air
- Water underneath the
tub
• Air hose loosened on:
- Blower
- Air distributor
- Air nozzle
• Hydro hose loose on:
- Pump
- Hydro nozzles
• Drain/overfl ow defective?
• Seals on nozzles leaking?
• Acrylic material damaged?
• Tub infl ow connection leaking?
• Tighten hose clamp / disconnect and
reconnect hose
• Retighten hose clamp
• Replace seals
• Replace seals
• Repair acrylic material with repair sets
• Replace seals
• Underwater lighting does
not switch on
• Is the water level high enough?
• Lighting element defective?
• Is voltage applied?
- Are fuses inserted?
- Malfunction in electrical mains
- Are the plug connections to the control correctly seated?
• Water level sensor does not react
• Continue to fi ll tub
• Replace lighting element
•
- Insert fuse
- Call electrician
- Pull and reinsert plug
• Adjust sensor
• Replace sensor
Summary of Contents for Luxusline Duo Imaza 750
Page 2: ...2...
Page 35: ...35 5 16 17 18 1 2 3 8 4 6 7 9 10 11 12 15 14 13 English English Equipment...
Page 75: ...75 97308000 English Service Replacement of rechargeable battery in the Poolkontrol...
Page 77: ...77 English Declaration of performance...
Page 78: ...78 Declaration of performance...