background image

manual

WWW.CLF-LIGHTING.COM

V1.0 JANUARY 2022

softlED 200 VW

Summary of Contents for SOFTLED 200 VW

Page 1: ...manual WWW CLF LIGHTING COM V1 0 JANUARY 2022 softlED 200 VW ...

Page 2: ...cables 6 Relaying power to other devices 6 Data link 6 Tips for reliable data transmission 6 Physical installation 7 Fastening the fixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control mode 9 Onboard control menus 11 DMX protocols 12 Specifications 13 WWW CLF LIGHTING COM ...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 ...

Page 4: ... PROTECTION FROM ELECTRIC SHOCK Disconnect the fixture from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the fixture check that all power distribution equipment an...

Page 5: ...e of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 3 meters and above light output is harmless to the naked eye provided that the eye s natural aversion response is not overcome Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may co...

Page 6: ...WWW CLF LIGHTING COM 4 DMX in out Powercon thrue in out Manual cct brightness Fixture overview ...

Page 7: ...tellectual property is exclusively reserved We will file a lawsuit on condition that it is illegally copied and imitated AC Power Warning Read Safety Information starting on before connecting the fixtures to AC mains power Warning For protection from electric shock the fixture must be grounded earthed The power distributioncircuit must be equipped with a fuse or circuit breaker and ground fault ea...

Page 8: ...ture 2 Connect the DMX output of the fixture closest to the controller to the DMX input of the next fixture and continue connecting fixtures output to input Relaying power to other devices Warning Do not connect more 10 fixtures in total to AC mains power in one interconnected chain Power can be relayed to another device via the PowerCON TRUE 1 throughput socket If you daisy chain the fixtures in ...

Page 9: ...least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or cooling may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview if the f...

Page 10: ...ion press ENTER To escape a function or move back one level in the menu structure press MODE DMX address setting The DMX address also known as the start channel is the first channel used to receive instructions from the controller For independent control each fixture must be assigned its to a separate channel The DMX address can be configured by using the DMX ADDRESS menu in the control panel For ...

Page 11: ...2ch 3ch 5ch Dimmer Dimmer fine Strobe CCT Macro CCT WWW CLF LIGHTING COM 9 Control mode DMX control mode is selected in the CONTROL MODE menu The fixture can be controlled with 3 DMX control modes ...

Page 12: ...WWW CLF LIGHTING COM 10 control panel ...

Page 13: ...efault OFF Knobs Brightness CCT Function OFF Default Brightness CCT Fixed Color CW CW WW WW Static Color CCT 3200K 6000K Default 4000K Dimmer 0 225 Strobe 0 20 Software version V1 00 Used Time Total xxxxxH LED Total xxxxxH Info Temperature Current temperature xxx C Max temperature xxx C Min temperature xxx C RDM UID 0xxxxxxx Error message Cold Hot Error Factory Reset Load factory default YES NO Us...

Page 14: ...000 255 Dimmer 2 000 255 Dimmer fine 2 2 3 000 255 Color temperature Preset color temperature 000 010 No function 011 035 3200K 036 060 4000K 061 085 5000K 4 086 110 5600K 111 135 6000K 136 160 User1 161 185 User2 186 210 User3 211 235 User4 236 255 User5 3 5 000 255 Strobe ...

Page 15: ...ency 50 60HZ Light Source SMD LED Lens Matrix compound optical system Color Temperature 3200K 6000K adjustable CRI 97 Beam Angle 120 Dimming Range 16bit smooth dimming 0 100 DMX Channel 2CH 3CH 5CH Control System DMX512 Display Screen 4 Button LCD Screen IP Rating IP20 Ambient Temp 15 C 35 C Weight 6 9Kgs 9Kgs ...

Page 16: ...WWW CLF LIGHTING COM CLFLIGHTING SoftlED 200 VW ...

Reviews: