 INSTALLATION AND OPERATING INSTRUCTIONS

Note:

 When the ambient relative humidity is 1% lower than the 

selected relative humidity ratio percentage (RH %), the unit 
compressor will switch off and unit will operate at a Low (L)  
speed level.

Note:

 When the ambient relative humidity is 5% higher than the 

selected relative humidity ratio percentage (RH %), the unit will 
switch on and unit will operate at the selected SPEED setting.

Note:

 The unit will continuously run, regardless of the ambient 

relative humidity, when the CON (continuous dehumidification) 
mode is set.

5.   To select ON/OFF timer.

To set automatic OFF timer, press TIMER button when unit is 
powered ON; select the desired running time 1/2/4/8 hours 
respectively, timer LED lights will illuminate accordingly. Unit will 
automatically switch OFF once selected OFF time duration has 
lapsed. The screen will display time elapsed and remaining  
running time.

To set automatic ON timer, press TIMER button when unit is 
powered OFF or on standby mode, select the desired time for unit to 
start operating at 1/2/4/8 hours respectively, timer LED lights will 
illuminate accordingly. Timer symbol will be displayed on screen.

6.   To select auto dehumidification setting, press AUTO button, the 

AUTO LED light will remain illuminated. Unit will automatically 
adjust the humidity setting according to the ambient 
temperature.

Note:

 When the ambient relative humidity is less than or equal to 

24°C, the relative humidity ratio setting is 80%.When the ambient 
relative humidity is less than or equal to 24°C - 25 °C, the relative 
humidity ratio setting is 60%.When the ambient relative humidity  
is greater than or equal to 25°C, the relative humidity ratio setting 
is 40%.

Note:

 When AUTO humidity setting is activated, the previous 

relative humidity ratio or continuous mode will be deactivated.

7.   As unit operates, condensed water will drain into water 

reservoir. When water reservoir is full unit will beep 10 times 
and WATER FULL 

 indicator light will illuminate and all other 

indicator lights will turn orange. Unit will automatically stop 
operating. The water reservoir must be removed and emptied 
before unit will operate again. See Fig 1.

Note:

 Allow minimum of three minutes before turning unit on, after 

water reservoir is emptied.

Fig 1

Remove water 
reservoir in 
accordance with 
arrow direction

Summary of Contents for CLI-DH12

Page 1: ...CLI DH12 Installation Operating Instructions Air Dehumidification System ...

Page 2: ...sture from the air creating a drier healthier room environment Note Please read through the instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance with the installation instructions before it is used During the set up of this product if you have any questio...

Page 3: ... and noise Units must never be placed and operated on an angle as water spillage from water reservoir can occur Empty the water when water reservoir is full or not in use for a prolonged period Recommended operating temperature range is minimum 5 C RH 40 and maximum 35 C RH 90 Any servicing other than cleaning and user maintenance will violate the terms of this WARRANTY and warranty will be null a...

Page 4: ...r unplug unit with wet hands Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The use of accessory attachments not recommended by the appliance manufacturer may result in fire ...

Page 5: ...unplug the power cord Ensure unit is dried thoroughly before operation of the unit Do not put fingers or other objects in any openings of the unit During the set up of this product if you have any questions comments issues DO NOT RETURN TO STORE FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT FREE CALL 1300 764 325 ...

Page 6: ...Air inlet E Air Filter F Continuous Drainage Hose G Continuous Drainage Outlet For hose connection H Water Reservoir Continuous drainage hose is an extra drainage option hose does not need to be connected if using the water reservoir to catch condensed water A PARTS IDENTIFICATION DIAGRAM F G H A B ...

Page 7: ... dehumidification speed is set at High H Note Unit will run on CON continuous dehumidification mode unless a room relative humidity ratio HUMID or the AUTO dehumidification is selected 3 To select the dehumidification mode press SPEED button to select High H or Low L respectively Note When the temperature sensor detects the ambient room temperature to be higher or equal to 32 C the unit fan speed ...

Page 8: ...s respectively timer LED lights will illuminate accordingly Timer symbol will be displayed on screen 6 To select auto dehumidification setting press AUTO button the AUTO LED light will remain illuminated Unit will automatically adjust the humidity setting according to the ambient temperature Note When the ambient relative humidity is less than or equal to 24 C the relative humidity ratio setting i...

Page 9: ...sor is activated to restart unit unplug unit and restart again 3 Failure of Humidity Temperature Sensor When the connection wire between the humidity and temperature sensor is disconnected the humidity CON light will blink and switch unit into continuous dehumidifying mode If the temperature evaporator sensor becomes open circuit or short circuit the DEFROST light will start blinking Unit will ope...

Page 10: ... F MAINTENANCE AND REPAIR Before carrying out any maintenance or cleaning of the unit make sure that the power to the unit is turned off and power cord is removed from the power socket External cleaning of unit Do not clean unit with any abrasive cleaning agents or solvents Do not apply any water directly to the unit of cleaning Only use a soft clean cloth for all cleaning purpose Cleaning Filter ...

Page 11: ...ervoir and allow minimum of two days for unit to dry before packing away Keep unit in a dry and ventilated place Repair If the unit or power cord is damaged stop using immediately and bring the unit to authorised service center for repair never attempt to dismantle repair or modify the unit by yourself Warranty will be null and void ...

Page 12: ...f problem persists call customer care No Air 1 Unit is not plugged into wall socket 2 Humidity ratio if set has been reached 3 Air outlet blocked 4 Water Reservoir is full 1 Check connection to wall socket 2 Wait 30 minutes turn unit back on 3 Ensure there are no objects obstructing air outlet 4 Empty water reservoir Unit Overheating 1 Air ventilation around unit not sufficient 2 Humid Air Inlet o...

Page 13: ...nage hose not connected to spigot properly 3 Continuous drainage hose outlet not over water drain 1 Reinstall water reservoir 2 Check hose connection 3 Check hose outlet is flowing into water drain Beeping Alarm Noise 1 Water Reservoir is Full 2 Ambient temperature is either less than or equal to 0 C or greater than or equal to 40 C 1 Remove and empty water reservoir 2 Turn off unit and restart or...

Page 14: ...anship in the manufactured product Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a maj...

Page 15: ......

Page 16: ...CUSTOMER HOTLINE 1300 764 325 Aquaport Corporation Pty Ltd PO Box 81 Findon SA 5023 Australia Telephone 1300 764 325 Facsimile 08 8354 0722 Email aquaport aquaport com au Web www aquaport com au ...

Reviews: