© 2008 Directed Electronics—all rights reserved
adjust mode:
Press/hold the button of the remote control for 8 seconds or
until the Amber LED turns on and you hear one long beep.
Press/hold the button 1.5 seconds or until the amber led flashes
once:
The control module will emit one long chirp, enter adjust mode, and
send the current level of information back to the transmitter. The
remote will beep once and the button LEDs will turn on to indicate the
current level.
Press the Arm, Disarm, or Remote Start buttons to adjust the sensor
level.
Arm button:
Pressing the button will increase the sensitivity one
level. The siren chirps twice, the remote beeps twice and the LEDs
increase in level.
Disarm button:
Pressing the
1
3
4
5
6
2
A U
X
button will decrease the sensitivity
one level. The siren chirps once, the remote beeps once and the LEDs
decrease in level.
Remote Start button:
Pressing the
button will reset to default
level 7. The siren chirp three times, the remote beeps three times and
the LEDs reset.
To exit the adjust shock sensor mode from the remote control:
Press the button. The control module is exited.
To exit the adjust shock sensor mode from the control module:
Open an entry point or turn on the ignition, the control module will
emit one long chirp and tell the remote to exit adjust mode.
To exit programming:
▀
▀
▀
▀