background image

 

2. Introduction 
2.1 

Depending on the power cord fitted this fan heater may be used in certain 

locations such as households, warehouses and workshops, building sites or 
greenhouses. It incorporates a thermostat and a self-resetting thermal cut-out to 
control the heating elements. The thermostat detects the air temperature and 
controls the heat output of the appliance. The fan motor is not controlled by this 
thermostat and it continues working when the thermostat switches off the heating 
element. The self-resetting thermal cut-out will switch off the heater to prevent 
overheating.

 

There is an additional thermostat to control the fan motor. If the 

temperature inside heater is high, and the heater is connected to the power supply, 
the thermostat may cause the fan to continue to run independently of the heat 
selector dial setting. For example, after heating operation, when the heater is 
turned off, the fan motor will continue to operate to reduce the temperature inside 
the unit.   

 
2.2

  When using  the heater for the first time, you may notice  a slight emission of 

smoke. This is quite normal and it will stop after a short time. The heating element 
is  made  of  stainless  steel  which  was  coated  with  a  protective  oil  during 
manufacturing. The smoke is caused by the residual protective oil when the heater 
is switched on for the first time. 

 

3.

 

Technical specifications

 

                      Model 

HCK-TP15 

HCK-TP30 

Voltage 

380-400V 

380-400V 

Required power 

15000W 

30000W 

Current 

21.7-22.8A 

43.3-45.6A 

Setting 

110/5000/10000/15000W 

70/15000/30000W 

Self-resetting Thermostat 

65°C 

80°C 

Product Dimensions (mm)

 

495X520X860 

645X565X860 

Net Weight (kg) 

21.7 

31.2 

 
3.1

 Housing made of heat-resistant powder coated steel plate. 

3.2

 Supplied with industrial socket installed in the heater. A 3-Phase cable (not 

included) of the correct rating fitted with a suitable connector is required to connect 
the HCK-TP15 and HCK-TP30 to the power supply. 

 
 
 
 

Summary of Contents for HCK-TP15

Page 1: ...tion and they are supervised or given instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years should not plug in...

Page 2: ...r heating operation when the heater is turned off the fan motor will continue to operate to reduce the temperature inside the unit 2 2 When using the heater for the first time you may notice a slight...

Page 3: ...the power cord is too long and heavy it could cause the cable to work loose from the socket in the unit or cause a trip hazard The specification for the cable and socket for each model is shown below...

Page 4: ...use review the marking on the power cord Depending on the power cord type this appliance may be used in different ambient conditions Type You can use the appliance in Do not use in H07RN F household w...

Page 5: ...e appliances and the safety of the appliance operators If in any doubt about electrical safety contact a qualified electrician 5 1 3 Ensure that the insulation on all cables and on the appliance is sa...

Page 6: ...lectric shock or leakage current never use the appliance with wet hands or operate the appliance when there is water on the power cord 5 2 16 Do not dispose of electrical appliances as unsorted munici...

Page 7: ...ool down To keep the outside of the heater case clean wipe it regularly with a soft sponge Where the outside of the case is heavily soiled wipe it with a sponge dipped in 50 C water and mild detergent...

Page 8: ...thermostat has operated Set the thermostat to a higher temperature and listen to hear it operating If there is no click and the thermostat is not damaged the heater will automatically switch on when t...

Page 9: ...eat output elmin N A kW Single stage heat output and no room temperature control no In standby mode elSB N A W Two or more manual stages no room temperature control no With mechanic thermostat room te...

Page 10: ...heat output elmin N A kW Single stage heat output and no room temperature control no In standby mode elSB N A W Two or more manual stages no room temperature control no With mechanic thermostat room t...

Page 11: ...Should this unit be operated under conditions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to undertake unapproved servicing or make modi...