9
D
ESCALING FUNCTION
Before you setting descaling program, check the water tank to make sure that
there is enough pure water in the water tank.
1.
Open the door and add proper amount of scale remover into the evaporation
pan, then close the door.
2.
Press POWER button once.
3.
Press
or
button repeatedly until display shows "A-1" and "
".
4.
Press OK button once.
5.
Press
or
button repeatedly, or press and hold
or
button to
select "A-24".
6.
Press OK button once.
NOTE:
During descaling, you can press
or
button repeatedly, or press and
hold
or
button to adjust descaling time, no less than 22 minutes is
recommended.
When the system reminds the user to remove the scale, the display screen
displays "dESC" and flashes. At this time, the "dESC" icon will disappear
automatically after the descaling is set and the operation is over; otherwise,
the prompt will always exist.
C
ALIBRATION FUNCTION OF BOILING POINT
Before calibration, check the water tank to make sure that there is enough pure
water in the water tank.
In order to user can use this product at different altitudes, it provides the function
of boiling point calibration based on actual elevation.
In standby mode and oven door is closed, press and hold OK button more than 5
seconds, the display will show
”0:15h”. the oven start calibration boiling point.
NOTE:
During calibration process, do not press POWER button or open the oven
door. Otherwise, the calibration fails.
During calibration, you can press
or
button repeatedly, or press and
hold
or
button to adjust calibration time.