background image

97B0117N02

*97B0117N02*

©2013 ClimateMaster, Inc.
ClimateMaster, Inc.
7300 SW 44th Street
Oklahoma City, OK 73179

1.405.745.6000
www.climatemaster.com

Summary of Contents for iGate Connect

Page 1: ...iGate Connect Thermostat Installation Manual...

Page 2: ...mation 3 Approvals 4 FCC Compliance Statement 4 Specifications 8 Wiring Requirements 8 INSTALLING THE iGate Connect THERMOSTAT 9 Step 1 Power Off HVAC Equipment 9 Step 2 Remove Existing Thermostat 9 S...

Page 3: ...nfig 14 Equipment 14 Thresholds 18 Humidity Control Settings 21 Service Mode 21 Sensors 27 Reset HVAC Equipment Settings 29 Performing a Hardware Reset 29 Rebooting the iGate Connect Thermostat 29 Con...

Page 4: ...This Page Intentionally Left Blank...

Page 5: ...ough all aspects of the installation To ensure an on going service relationship with your customers please register all of your ClimateMaster thermostats in your Contractor Portal Technical Support Ou...

Page 6: ...ual The iGate Connect thermostat is designed to be mounted on the homeowner s wall in a convenient location Caution Disconnect electric power to the HVAC system before installing this product Failure...

Page 7: ...iGate Connect thermostat is designed to operate with the ClimateMaster Trilogy Geothermal Unit The ClimateMaster iGate Connect thermostat supports the following equipment Equipment Supported Trilogy w...

Page 8: ...ns may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference...

Page 9: ...e less than 20cm during normal operation Industry Canada IC Compliance Notice This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditio...

Page 10: ...qu aucune interf rence ne se produira dans une installation donn e Si ce mat riel cause des interf rences nuisibles la r ception radio ou t l visuelle ce qui peut tre tabli en teignant et en ralluman...

Page 11: ...xploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le b...

Page 12: ...to 55 C Humidity Range Display 20 to 90 R H Sensitivity 5 R H Operating 5 to 95 R H non condensing Dimensions Thermostat 5 5 W x 3 25 H x 1 D 139 5mm H x 82 5mm W x 25mm D Power 24 VAC 3VA maximum Wi...

Page 13: ...g the iGate Connect thermostat disconnect the power to the heating and air conditioning equipment Step 2 Remove Any Existing Thermostat Disconnect the wires to the existing thermostat if applicable an...

Page 14: ...sing the backplate as a template mark the location of the mounting holes on the wall as shown below 4 Move the backplate out of the way and make holes where indicated in step 3 The mounting holes can...

Page 15: ...agram 2 Attach the iGate Connect thermostat to the backplate Ensure that the pins on the thermostat align with the terminal block on the backplate Wiring Diagram The following diagram shows how to con...

Page 16: ...change the temperature access features and configure settings Using the Navigation Buttons The navigation buttons located on the right of the iGate Connect thermostat let you select options and contr...

Page 17: ...l available options If a menu is currently displayed pressing MENU will cancel any unsaved changes and return to the Home screen BACK On a menu screen press BACK to go back to the previous screen On S...

Page 18: ...it will cycle off Range will depend on unit model Max Heating Capacity Configures the maximum unit heating capacity When the space requires a heating capacity above this setting the unit will call for...

Page 19: ...imum unit cooling capacity When the space requires a cooling capacity below this setting the unit will cycle off Range will depend on unit model Max Cooling Capacity Configures the maximum operational...

Page 20: ...epend on unit model Heat Off Delay This setting determines whether or not and how long the blower will continue to operate after the compressor has cycled off at the end of each heating cycle Valid ra...

Page 21: ...ate for the heating mode The vFlow device will adjust the flow to maintain this temperature difference between the entering and leaving water during the heating mode to this setting Valid range 5 0 F...

Page 22: ...tting the thresholds Only the applicable threshold settings will be displayed Allow Auto Heat Cool Allows the user to be able to operate the unit in the auto changeover heat cool mode Select Yes for t...

Page 23: ...the space is being rejected into the potable hot water If the space temperature rises more than this amount the potable water heating mode will be terminated and the cooling mode will reject the heat...

Page 24: ...ll cause the unit to respond more rapidly to changes in space temperature A higher setting will cause the unit to respond more slowly to changes in space temperature Valid range 1 to 10 Default is 5 C...

Page 25: ...is greater than the setpoint to improve dehumidification i e acts as a dehumidistat The cooling airflow will not be reduced when the space humidity is below the setpoint Both or None Service Mode Unit...

Page 26: ...lid range 0 to 100 Default is 41 DHW Pump Speed if applicable Sets DHW pump speed for manual operation mode Valid range 0 to 100 Default is 0 Comp Target Speed Displays current compressor target speed...

Page 27: ...umption of the blower in watts ECM Blower Static not used Leaving Air displays the temperature of the air leaving the unit Entering Air displays the temperature of the air entering the unit Loop Diagn...

Page 28: ...mpressor discharge line Suction Pressure displays the refrigerant suc tion pressure Suction Saturation displays the saturation temperature of the refrigerant suction pres sure Suction Temp displays th...

Page 29: ...expansion valve Water Coil EEV1POS displays the position of the heating electronic expansion valve in steps 0 fully open 1040 fully closed Air Coil EEV2 Stat displays the status on or off of the cooli...

Page 30: ...ON Diag Master OFF Diag Slave SW1 3 ON ACC K3 ACC1 Tracks compressor OFF ACC K3 ACC1 Tracks blower SW1 4 ON ACC K4 ACC2 Tracks compressor OFF ACC K4 ACC2 Tracks blower SW1 5 ON ACC K7 Tracks compress...

Page 31: ...sensors to be displayed at thermostat Sensors RS 1 sensor name This is sensor number 1 It will not display a name until a name has been entered o Name Establishes a name for sensor 1 o Type Configure...

Page 32: ...lishes a name for sensor 1 o Type Configures the type of sensor The sensor may be a dry contact or a temperature sensor If a temperature sensor the installer selects the manufacturer model and a tempe...

Page 33: ...tead Performing a Hardware Reset In rare circumstances static electricity or power surges may interrupt the operation of the thermostat forcing a hardware reset Rebooting the iGate Connect Thermostat...

Page 34: ...b portal You can set the Last Service date turn the Reminder On or Off and to set the Frequency of the maintenance interval in months Air Filter Generates an alert that indicates it is time to clean o...

Page 35: ...act information will be displayed on the screen If the homeowner registers the thermostat the alert will be emailed to them and be displayed in the web portal Low Temp Alert Sets the temperature at wh...

Page 36: ...t Generates an alert when the space humidity exceeds the selected amount The range can be Off Set humidity set point of 5 to 95 Display Alerts on Thermostat Select No if you do not want any of the ale...

Page 37: ...ntities and ClimateMaster or its authorized reseller or distributor as applicable shall provide a fill refund of the purchase price paid within fourteen days of its receipt of the return In considerat...

Page 38: ...and contemplated by the User Manual provided that the Software may only be used for its personal and private use in connection with the use of the Product and b use the User Manual provided by ecobee...

Page 39: ...o protect its rights concerning the Software or other intellectual or proprietary rights LICENSEE agrees not to contest object to or otherwise oppose an application for equitable relief by ecobee in s...

Page 40: ...SHALL ECOBEE ITS SHARE HOLDERS AFFILIATES CONTRACTORS SUPPLIERS AND AGENTS AND THEIR RESPECTIVE DIRECTORS OFFICERS AND EMPLOYEES COLLECTIVELY THE ECOBEE PARTIES BE LIABLE TO LICENSEE OR ANY THIRD PART...

Page 41: ...tario in respect of all matters and disputes arising hereunder 16 Export Law Assurances LICENSEE acknowledges that the Software may be subject to export and import control laws and agrees to comply fu...

Page 42: ...97B0117N02 97B0117N02 2013 ClimateMaster Inc ClimateMaster Inc 7300 SW 44th Street Oklahoma City OK 73179 1 405 745 6000 www climatemaster com...

Reviews: